Viewing Study NCT06255002


Ignite Creation Date: 2025-12-25 @ 3:54 AM
Ignite Modification Date: 2025-12-26 @ 2:44 AM
Study NCT ID: NCT06255002
Status: RECRUITING
Last Update Posted: 2025-09-12
First Post: 2023-12-05
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Concordance Between the Measurement of Whole Blood Fibrinogen by the qLabs®FIB Analyzer and Its Measurement by Conventional Method (Clauss Fibrinogen) in the Context of Severe Postpartum Haemorrhage
Sponsor: Assistance Publique - Hôpitaux de Paris
Organization:

Study Overview

Official Title: Concordance Between the Measurement of Whole Blood Fibrinogen by the qLabs®FIB Analyzer and Its Measurement by Conventional Method (Clauss Fibrinogen) in the Context of Severe Postpartum Haemorrhage: a Prospective Multicenter Non-interventional Study
Status: RECRUITING
Status Verified Date: 2025-09
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: FIB-HPPS
Brief Summary: In France in 2021, 11.6% of deliveries were complicated by a postpartum haemorrhage (PPH), including 3.0% by severe PPH (the bleeding volume exceeds 1000 ml). Severe PPH is the 5th cause of maternal death (8.4% or 1.2 deaths per 100,000 live births). These deaths were considered preventable in 90% of cases. A plasma fibrinogen concentration below 2 g/L is considered as a critical threshold which constitutes a marker of severity of PPH and is significantly associated with the occurrence of severe PPH. Measuring the concentration of fibrinogen using a rapid test, simple to perform and interpret, available in the delivery room could optimize the management of severe PPH. The qLabs®FIB analyzer distributed by the Stago Biocare laboratory for the rapid determination of the fibrinogen concentration at the patient's bedside could meet this objective.
Detailed Description: In France in 2021, 11.6% of deliveries were complicated by postpartum hemorrhage (PPH), including 3.0% by severe PPH (the bleeding volume exceeds 1000 ml). Severe PPH is the 5th cause of maternal death (8.4% or 1.2 deaths per 100,000 live births). These deaths were considered preventable in 90% of cases. A plasma fibrinogen concentration below 2 g/L is considered as a critical threshold which constitutes a marker of severity of PPH and is significantly associated with the occurrence of severe PPH. Measuring the concentration of fibrinogen using a rapid test, simple to perform and interpret, available in the delivery room could optimize the management of severe PPH. The qLabs®FIB analyzer distributed by Stago Biocare laboratory for the rapid determination of the fibrinogen concentration at the patient's bedside could meet this objective.

The hypothesis of the study is a concordance between the measurement of fibrinogen by the qLabs®FIB Monitoring system and by the Clauss fibrinogen assay in laboratory to identify patients with a fibrinogen level \< 2 g/L.

The prospects are to provide an easy-to-use delocalized biology tool for early diagnosis of a fibrinogen concentration \< 2g predictive of an unfavorable evolution in the context of severe PPH.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: False
Is an FDA AA801 Violation?: