Viewing Study NCT00827905


Ignite Creation Date: 2025-12-25 @ 3:28 AM
Ignite Modification Date: 2025-12-26 @ 2:09 AM
Study NCT ID: NCT00827905
Status: COMPLETED
Last Update Posted: 2010-08-06
First Post: 2009-01-21
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Substantial Equivalence Study for Kai Sensors RSpot Non-Contact Respiratory Rate Spot Check
Sponsor: Kai Medical, Inc.
Organization:

Study Overview

Official Title: Remote Doppler System to Measure Heart Rate and Breathing Pattern
Status: COMPLETED
Status Verified Date: 2010-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The purpose of this study is to determine whether the respiratory rate provided by the Kai Sensors RSpot 100 Non-Contact Respiratory Rate Spot Check is as accurate as that provided by the Welch Allyn Propaq Encore model 242 and the Embla Embletta system with Universal XactTrace respiratory effort sensor and Somnologica for Embletta software.
Detailed Description: Currently, medical professionals obtain respiratory rate for vital signs assessments either by counting the number of breaths during a 15, 30, or 60 second interval and multiplying to obtain breaths per minute, or by reading the respiratory rate off of a multiparameter vital signs monitor (such as a Welch Allyn Propaq Monitor), that provides respiratory effort information based on the change of AC impedance through ECG leads. The Respiration channel (RESP) of the Welch Allyn Propaq is intended to detect the rate or absence of respiratory effort, deriving the signal by measuring the AC impedance between the selected terminals of the ECG electrodes. The RSpot 100 Non-Contact Respiratory Rate Spot Check provides an alternative to the medical professional counting respiratory rate or reading the rate from a vital signs monitor designed for continuous respiratory rate monitoring. The Kai Sensors RSpot 100 Non-Contact Respiratory Rate Spot Check is used for a one-time measurement of respiratory rate as part of a vital signs assessment in the hospital or other clinical settings.

In this study, the RSpot is operated simultaneously with two other systems that provide a respiratory rate: Welch Allyn Propaq Encore model 242 and Embletta system with Universal XactTrace and Somnologica software. A respiratory rate is also obtained by counting respiratory excursions for the same duration as the RSpot measurement interval, 15, 30, or 60 seconds. The rates obtained from each of the four measurement methods are then compared.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
RA-2008-061 None None View