Viewing Study NCT03548805


Ignite Creation Date: 2025-12-25 @ 3:10 AM
Ignite Modification Date: 2025-12-26 @ 1:49 AM
Study NCT ID: NCT03548805
Status: COMPLETED
Last Update Posted: 2023-12-12
First Post: 2018-03-16
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Ologen® Collagen Matrix Versus Mitomycin-C in Patients With Juvenile-onset Open Angle Glaucoma
Sponsor: L.V. Prasad Eye Institute
Organization:

Study Overview

Official Title: Randomized Controlled Study to Evaluate Safety and Efficacy of Ologen® Collagen Matrix Versus Mitomycin-C in Patients With Juvenile-onset Open Angle Glaucoma
Status: COMPLETED
Status Verified Date: 2023-12
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: To the best of Investigator knowledge, no studies to this date have compared the safety and efficacyof ologen® Collagen Matrix to MMC in exaggerated healing response among JOAG patients. Given that,filtration surgery is usually less successful in patients with juvenile glaucoma; the purpose of this study is to compare these two adjuvant therapies in exaggerated healing response among JOAG patients. Investigator hypothesis is that trabeculectomy with ologen® Collagen Matrix would be as effective as MMC in IOP control, with prominent bleb morphology as compared to MMC bleb.
Detailed Description: Standard trabeculectomy All trabeculectomy surgeries will be performed under peribulbar anesthesia.Under aseptic surgical technique, superior rectus suture will be placed using 4-0 silk and a fornix-based conjunctival flap will be performed. Sub-Tenon dissection and hemostasis may be performed as required.A half-thickness 4 x 4mm rectangular/ triangular scleral flap will be dissected up to clear cornea, and a 2 × 2 mm deep scleral block will be excised and peripheral iridectomy will be performed. The scleral flap will be closed with one or two 10-0 nylon sutures and conjunctiva will be closed with 8-0 vicryl suture. Releasable sutures may be applied to the scleral flap if needed.

ologen® Collagen Matrix ologen® Collagen Matrix approved by Indian health authority with registration numberof MD-1517 (valid till Mar-15-2018) will be provided by Aeon Ajanta India Pvt. Ltd. free of cost for this clinical research only.

The following table summarizes the model number, shape and manufacturer of ologen® Collagen Matrix to be used in this clinical research.

Product Model Shape Size Manufacturer Country of Origin Product Registration ologen® Collagen Matrix 830601 Round cylindrical 6mm (diameter) x 2mm (thickness) Aeon Astron Europe B. V. The Netherlands MD-1517 (valid till Mar-15-2018)

Mitomycin C Mitomycin-C Kyowa®; Kyowa Hakko Kogyo Co., Ltd. will be used. 0.02% solution of MMC will be prepared freshly on the day of planned surgery.

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: