Viewing Study NCT01550809



Ignite Creation Date: 2024-05-06 @ 12:21 AM
Last Modification Date: 2024-10-26 @ 10:48 AM
Study NCT ID: NCT01550809
Status: COMPLETED
Last Update Posted: 2012-08-29
First Post: 2012-02-28

Brief Title: New Strategies for Postprandial Glycemic Control Using Insulin Pump Therapy
Sponsor: Fundación para la Investigación del Hospital Clínico de Valencia
Organization: Fundación para la Investigación del Hospital Clínico de Valencia

Study Overview

Official Title: New Strategies for Postprandial Glycemic Control Using Insulin Pump Therapy Feasibility of Insulin Dosing Based on Information From Continuous Glucose Monitoring
Status: COMPLETED
Status Verified Date: 2012-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Achieving near-normoglycemia has been established as the main objective for most patients with type 1 diabetes T1DM However insulin dosing is an empirical process and its success is highly dependent on the patients and physicians skills either with multiple daily injections MDI or with continuous subcutaneous insulin infusion CSII the gold standard of insulin treatment

Postprandial glucose control is one of the most challenging issues in the everyday diabetes care Indeed postprandial glucose excursions are the major contributors to plasma glucose PG variability of subjects with T1DM and the poor reproducibility of postprandial glucose response is burdensome for both patients and healthcare professionals

During the past 10-15 years there has been an exponentially increasing intrusion of technology into diabetes care with the expectation of making life easier for patients with diabetes Some tools have been developed to aid patients in the prandial bolus decision-making process ie bolus advisors which have been implemented in insulin pumps and more recently in the newest generations of glucometers Currently the availability of continuous glucose monitoring CGM has opened new scenarios for improving glycemic control and increasing understanding of post-prandial glycemic response in patients with diabetes

Results from clinical studies suggest that sensor-augmented pumps SAPmay be effective in improving metabolic control especially when included as part of structured educational programs resulting in patients empowerment Similarly preliminary results from pilot studies indicate that automated glycemic control especially during nighttimebased on information from CGM is feasible However automatic management of meal bolus is currently one of the main challenges found in clinical validations of the few existing prototypes of an artificial pancreas Indeed fully closed-loop systems where information about meals size and timing is not given to the system have shown poor performance with postprandial glucose higher and post meal nadir glucose lower than desired This has promoted other less-ambitious approaches where prandial insulin is administered following meal announcement semi closed-loop However despite the use of meal announcement currently used algorithms for glucose control the so-called PID and MPC show results that are not yet satisfactory due to the risk of producing hypoglycemia

One of the limitations of the current open-loop bolus advisors and closed-loop control strategies is that glycemic variability is not taken into account As an example settings of CSII consider inter-individual variation of the parameters insulincarbohydrates ratio correction dose etc but disregard the day-to-day intra-individual variability of postprandial glucose response Availability of massive amount of information from CGM together with mathematic tools may allow for the characterization of the individual variability and the development of strategies to cope with the uncertainty of the glycemic response to a meal

In this project a rigorous clinical testing of a CGM-based user-independent algorithm for prandial insulin administration will be carried out in type 1 diabetic patients treated with insulin CSII

First of all an individual patients model characterizing a 5-hour postprandial period will be obtained from a 6-day CGM period The model will account for a 20 uncertainty in insulin sensitivity and 10 variability in the estimation of the ingested carbohydrates Based on this model derived from CGM a mealtime insulin dose will be calculated referred as iBolus Then the same subjects will undergo standardized meal test studies comparing the administration of a traditional bolus tBolus based on insulin to CHO ratio correction factor etc with the CGM-based prandial insulin delivery iBolus

Significant advances in postprandial control are expected Should its efficiency be demonstrated clinically the method could be incorporated in advanced sensor augmented pumps as well as feedforward action in closed-loop control algorithms for the artificial pancreas in future work
Detailed Description: Over the last 30 years even with the development of new glucose monitoring techniques and the availability of new insulin preparations with more physiological profiles SC continuous administration systems were still not able to be universal efficient and safe systems able to achieve a near-normalization of glucose levels in diabetic patients Indeed in developed countries only one third of diabetic patients meet criteria for good metabolic control ie glycosylated haemoglobin 7

During the past 10-15 years there has been an exponentially increasing intrusion of technology into diabetes care with the expectation of improving metabolic control and making life easier for patients with diabetes In the last years some tools have been developed to aid patients in the prandial bolus decision-making process as the bolus advisors which are implemented in insulin pumps and more recently in newest generations of glucometers Currently the availability of continuous glucose monitoring CGM has opened two scenarios

1 Open-loop control strategies In the shortmid term CGM may help in the implementation of more effective strategies of insulin treatment especially in CSII treated patients with the development of smarter pumps sensor augmented pumps which use the information from the CGM to tune insulin infusion
2 Closed-loop control strategies In the long term CGM may allow for automated glucose control the so-called artificial pancreas

The artificial pancreas would represent the ideal solution for the attainment of the therapeutic goals needed to prevent chronic complications of diabetes Indeed in the last two decades technological progresses have fuelled research on closed-loop glucose control systems aiming for effective treatment of diabetic subjects Preliminary studies using off-the-shelf insulin pumps and continuous glucose monitoring CGM sensors have suggested that in research settings closed-loop systems that automatically dispense insulin can achieve better glucose control than open-loop systems in which people have to take dosing decisions Such promising results prompted the Juvenile Diabetes Research Foundation JDRF to push the research forward by launching its Artificial Pancreas Project in 2006 Also the US Food and Drug Administration FDA designated the artificial pancreas as a priority within its Critical Path Initiative However due to its complexity only a few prototypes so far have been developed and tested in controlled clinical settings

Among problems related to glycemic closed-loop control management of postprandial glycaemic excursions is a key issue in the future artificial pancreas Indeed meal-induced perturbations on glucose control is one of the major problems to counteract and the main challenge found in current clinical validations of the few existing prototypes of closed-loop glycemic control systems

The first significant clinical result regarding fully automated closed loop in the fasting condition comes from Medtronic Inc who demonstrated the feasibility of a fully automated closed loop system in 10 adults with type 1 diabetes mellitus using an external pump CSII a sensor for continuous subcutaneous glucose monitoring CGM and a control algorithm called ePID This algorithm consists of a classical Proportional-Integral-Derivative controller plus insulin on-board feedback Since then several initial clinical trials of closed-loop control have been made to prove the feasibility of other control algorithms like Model Predictive Control MPC MPC has obtained positive results in type 1 diabetic patients and also in Intensive Care Units

Different approaches have been suggested to deal with meal disturbances in these controllers Fully closed-loop systems where information about meals size and timing is not given to the system have shown poor performance with postprandial glucose higher and post-meal nadir glucose lower than desired This has promoted other less-ambitious approaches where meals are announced to the system generating a feed-forward action like for instance a prandial insulin bolus semi closed-loop Hybrid approaches have also been proposed where only a percentage of the prandial bolus is applied priming bolus and the rest is left to the closed-loop controller

Clinical studies have demonstrated the efficacy of these solutions to reduce postprandial excursions during closed-loop control versus fully closed-loop systems showing that first generations of an artificial pancreas will require announcement of meals and priming insulin boluses

However despite the use of meal announcement the main challenge of control algorithms is still the avoidance of overcorrection An aggressive-enough tuning for a low post-prandial glucose peak may cause an accumulation of insulin producing a late hypoglycemia This imposes the consideration of constraints on residual insulin activity insulin-on-board both in PID and MPC-based systems However despite the inclusion of constraints clinical results during a meal of PID and MPC are not yet satisfactory

Interval techniques have shown to be particularly suitable to deal with constraints under uncertainty leading to more robust solutions and potentially reducing the risk of hypoglycaemia while maintaining good performance These techniques were first introduced by Bondia et al in 2009 who proposed a set-inversion-based algorithm for calculation of meal-related insulin This algorithm computed the feasible set of insulin profiles to fulfill the given constraints on postprandial glycemia according to a patients prediction model In particular physiological constraints were applied using postmeal guidelines from the International Diabetes Federation aiming at no hypoglycemia and two-hour glucose below 140 mgdL in a 5-hour time horizon A refined algorithm was presented by Revert et al in 2009 allowing for the determination of the optimal insulin administration mode standard square dual-wave or temporal basal decrementiBolus In this work an in silico validation using the FDA-accepted UVA simulator for the testing of control algorithms was performed Results of this study demonstrated the effectiveness of this strategy including the challenge of meals with high carbohydrate content

To date priming prandial boluses in the context of semi-automated glucose control are computed based on the patients insulin-to-carbohydrate ratio as currently done in standard CSII therapy In this latter bolus insulin is infused over the patients basal insulin rate usually following one of three available choices 1 simple bolus all of the insulin dose is administered as a bolus ie like with a pen or syringe 2 dual wave bolus a percentage of the insulin dose is administered as a bolus being the remaining insulin being infused as a square wave during a pre-specified time interval following the meal 3 square wave bolus all the insulin dose is administered as a square wave However the above mentioned study by Revert et al has demonstrated in silico ie by means of an FDA-accepted computer simulator that a coordinate action of basal and bolus insulin is required to maintain blood glucose in a physiological range in the postprandial state In particular a bolus greater than the standard one paralleled by a temporary reduction of the basal insulin infusion rate referred as iBolus which may be considered as a generalization of the superbolus concept introduced by Walsh et al is needed especially for meals with higher carbohydrate content

This study was planned to validate this new methodology for prandial insulin administration and it is expected to confirm the hypothesis that set-inversion techniques may be applied to SAP-CSII therapy Of note this strategy would represent the first attempt of developing a non-heuristic tool for mealtime insulin dosing It could be implemented not only in closed-loop strategies of glycemic control but also in open-loop strategies as an advanced bolus advisor in newest generations of insulin pumps

Primary objective

In type 1 DM subjects treated with CSII assessment and clinical validation of a new algorithm for optimization of postprandial glucose control the iBolus CGM-based prandial insulin administration in comparison with a standard bolus tBolus

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None
Secondary IDs
Secondary ID Type Domain Link
DPI2010-20764-C02-01 OTHER_GRANT Spanish Ministry of Science DPI2010-20764-C02-01 None