Viewing Study NCT04424433


Ignite Creation Date: 2025-12-25 @ 2:54 AM
Ignite Modification Date: 2025-12-26 @ 1:35 AM
Study NCT ID: NCT04424433
Status: COMPLETED
Last Update Posted: 2021-06-09
First Post: 2020-06-02
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Myocardial Strain Analysis in Anaesthetized Coronary Artery Disease Patients During Hyperoxia and Normoxaemia
Sponsor: Insel Gruppe AG, University Hospital Bern
Organization:

Study Overview

Official Title: Myocardial Strain Analysis in Patients With Coronary Artery Disease at Hyperoxia and Normoxaemia Prior to Coronary Artery Bypass Graft Surgery - a Randomized Crossover Study
Status: COMPLETED
Status Verified Date: 2021-06
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: Strecho-O₂
Brief Summary: The purpose of this study is to investigate the impact of supraphysiologic oxygen (hyperoxia) on myocardial function in anaesthetized patients with coronary artery disease.
Detailed Description: Up to 106 patients with coronary artery disease undergoing elective coronary artery bypass graft (CABG) surgery will be recruited to undergo this single visit study. In the timeframe shortly after the induction of anaesthesia and prior to the start of surgery, myocardial strain as a marker of cardiac function will be measured by transesophageal echocardiography (TEE). Echocardiography measurements will be acquired at two different oxygen states for each patient. The fraction of inspired oxygen (FiO2) will be adjusted to reach a normoxaemic state (FiO2=0.3) and a hyperoxic state (FiO2=0.8). Patients will be randomized to which oxygen level is investigated first. Thereafter, the study intervention is completed and anaesthesia and surgery will be performed as planned by the treating team. Echocardiography images will be analyzed in a blinded manner for cardiac function and systolic and diastolic strain parameters. The results will help anaesthesiologists to better weigh risks and benefits when selecting an inspired oxygen fraction in such patients, and will help to evaluate hyperoxia as a risk factor for myocardial injury.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
SNCTP000003911 OTHER Swiss National Clinical Trials Portal View