Viewing Study NCT05331833


Ignite Creation Date: 2025-12-25 @ 2:51 AM
Ignite Modification Date: 2025-12-26 @ 1:33 AM
Study NCT ID: NCT05331833
Status: COMPLETED
Last Update Posted: 2022-08-30
First Post: 2022-03-29
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Omitting Clinical Target Volume of Unresectable Stage III Non-small-cell Lung Cancer.
Sponsor: Jianguo Sun
Organization:

Study Overview

Official Title: Omitting Clinical Target Volume Under PET-CT Guidance in Unresectable Stage III Non-small-cell Lung Cancer.
Status: COMPLETED
Status Verified Date: 2022-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: About 20-30% of patients with stage III non-small cell lung cancer (NSCLC) are unresectable and definitive concurrent radiochemotherapy is the standard care. Intensity-modulated radiation therapy (IMRT) is a new radiotherapy technology, including gross tumor volume (GTV), clinical target volume (CTV), internal target volume (ITV), and planning target volume (PTV) as delineated target volumes. The treatment failure of local advanced NSCLC is mainly caused by local recurrence accounted for 50% and distant metastasis accounted for 50%. Local recurrence occurs both within the radiation field and outside the radiation field. Elective nodal irradiation (ENI) was designed before, however the adverse events (AEs) was not satisfactory. Afterwards, involved field radiotherapy (IFRT) showed that a reduced irradiation field did not increase local recurrence, and lowered the AEs Thus, IFRT has been broadly used in clinical work instead of ENI. IFRT still has disadvantages, including the risk of radiation respiratory events and radiation esophagitis, can the irradiation area be further reduced to reduce adverse reactions without affecting the efficacy? Positron emission tomography -computed tomography (PET-CT) can accurately assess primary tumor and metastatic lymph nodes in NSCLC patients better than CT . A meta-analysis of 39 clinical studies showed that the median sensitivity and specificity of PET-CT for the detection of lymph node involvement were 85% and 90%, respectively, while those of CT alone were only 61% and 79%, respectively. The radiotherapy application of PET-CT in image acquisition can ensure the delineation of both primary tumor and mediastinal lymph node metastasis. Under this condition, can the radiation field be further reduced to lower the dose to normal tissue and radiotherapy-associated AEs? A dosimetry study showed that when a dose of 60 Gy was given to the primary tumor and positive mediastinal lymph nodes, even if the CTV was omitted, a dose of 50 Gy was sufficient to cover the subclinical area.
Detailed Description: A dosimetry study showed that when a dose of 60 Gy was given to the primary tumor and positive mediastinal lymph nodes, even if the CTV was omitted, a dose of 50 Gy was sufficient to cover the subclinical area.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: