Viewing Study NCT00289133


Ignite Creation Date: 2025-12-25 @ 2:43 AM
Ignite Modification Date: 2025-12-26 @ 1:22 AM
Study NCT ID: NCT00289133
Status: COMPLETED
Last Update Posted: 2017-04-24
First Post: 2006-02-07
Is NOT Gene Therapy: False
Has Adverse Events: True

Brief Title: Gamma Vacuum Foil (GVF) Versus Cross-linked Polyethylene in Total Knee Arthroplasty Study
Sponsor: DePuy Orthopaedics
Organization:

Study Overview

Official Title: Prospective, Comparative, Randomized Study of GVF Versus Cross-linked Polyethylene in Total Knee Arthroplasty
Status: COMPLETED
Status Verified Date: 2017-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The purpose of this study is to evaluate long-term clinical and radiographic data between geometrically identical GVF and cross-linked polyethylene-bearing inserts in total knee arthroplasty.
Detailed Description: In 1996, Gamma Vacuum Foil (GVF) polyethylene was introduced as the first polyethylene to be gamma irradiated and packaged in an inert environment. This polyethylene, with its patented process and packaging, continues to be the only barrier-packaged process that is impermeable to both Hydrogen (H2) and Oxygen (O2), and allows the polyethylene to recombine and cross-link in the package. Though the new moderately cross-linked polyethylene being evaluated in this protocol is comparable to GVF geometrically and mechanically, the P.F.C.® Sigma™ cross-linked polyethylene also has the added benefit of being completely oxidatively stable both on the shelf and in-vivo.

The P.F.C. Sigma tibial tray component being assessed in this study is made of Cobalt Chrome (CoCr). The new CoCr tibial tray has the same design geometrically as the original titanium (Ti) tray, however, it features a highly polished top surface where it is joined to the polyethylene. This polished surface is designed to decrease the coefficient of friction between the polyethylene and the tray, thus minimizing backside wear. A comparative clinical study will be conducted to evaluate long-term clinical and radiographic data between geometrically identical cemented implants using GVF and crosslinked polyethylene tibial tray bearing inserts in Total Knee Arthroplasty (TKA) using the P.F.C. Sigma Total Knee System. Patients will be assigned to study treatment groups at random if they meet specific demographic and pathophysiologic criteria for cemented total knee arthroplasty. The anticipated duration of this investigation is a minimum six years, which includes a one-year enrollment phase.

The specific aims of this study are as follows:

1. Examine whether crosslinked polyethylene performs as well, if not better, than GVF polyethylene through standard clinical evaluations.
2. Evaluate long-term survivorship rates.
3. Report complications/adverse events.
4. Report radiographic findings of geometrically identical implants.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: