Viewing Study NCT05993533


Ignite Creation Date: 2025-12-25 @ 2:40 AM
Ignite Modification Date: 2025-12-26 @ 5:26 PM
Study NCT ID: NCT05993533
Status: UNKNOWN
Last Update Posted: 2023-08-15
First Post: 2023-08-07
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Comparison of the 'CTR' Ratio With Standard Haemostasis Parameters in the Follow-up of Patients Undergoing Heparin Therapy
Sponsor: Direction Centrale du Service de Santé des Armées
Organization:

Study Overview

Official Title: Comparison of the 'CTR' Ratio With Standard Haemostasis Parameters in the Follow-up of Patients Undergoing Heparin Therapy
Status: UNKNOWN
Status Verified Date: 2023-08
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: QuantiXa
Brief Summary: The Quantra(r) hemostasis analyzer (Stago) is a recent addition to the family of global hemostasis tests. It uses ultrasound-based technology to characterize the viscoelastic properties of a whole blood sample during coagulation. The Qplus(r) cartridge consists of independent channels, each containing different reagents that provide parallel measurements of 6 parameters.

This global test takes into account cellular elements such as platelets and red blood cells in clot formation, and also explores fibrinolysis. In addition, this test is of particular interest in delocalized biology, i.e. at the patient's bedside, and avoids the time-consuming laboratory centrifugation stage required for routine analyzers.

In practice, this test has been developed to monitor haemostasis in patients who may present with a range of coagulopathies of various etiologies, but also in the management of haemorrhagic patients, in order to adapt the administration of blood products in particular.

The Quantra (r) analyzer could therefore be of interest since it could be deployed in overseas operations to manage war casualties.

Recent studies (EACTAIC-ICCVA congress, October 2021) have shown that there is a good correlation between anti-Xa activity and the CTR (coagulation time ratio) parameter of the Quantra cartridge Qplus (TM), suggesting that this automated system could be used to manage anticoagulant therapy.
Detailed Description: None

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
2023-A00466-39 OTHER IDRCB View