Viewing Study NCT07126834


Ignite Creation Date: 2025-12-25 @ 2:32 AM
Ignite Modification Date: 2025-12-29 @ 3:32 AM
Study NCT ID: NCT07126834
Status: ACTIVE_NOT_RECRUITING
Last Update Posted: 2025-08-20
First Post: 2025-08-06
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: Voluntary Isocapnic Hyperpnea in Hypoxia to Mitigate Acute Mountain Sickness
Sponsor: Institute of Sport - National Research Institute, Poland
Organization:

Study Overview

Official Title: Could a Breathing Protocol Serve as a Non-Pharmacological Strategy to Mitigate Acute Mountain Sickness? A Randomized Crossover Trial.
Status: ACTIVE_NOT_RECRUITING
Status Verified Date: 2025-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This study investigates the effects of a brief Voluntary Isocapnic Hyperpnoea (VIH) on Acute Mountain Sickness (AMS) symptoms, SpO₂, blood pressure, and blood gas homeostasis in normobaric hypoxia, to evaluate whether such respiratory modulation may serve as a viable strategy to alleviate AMS symptoms. The investigation seeks to explore the physiological mechanisms underlying VIH in severe hypoxia (4200m asl) and furnish insight regarding practical means of providing immediate relief from AMS symptoms. Furthermore, given the scarcity of relevant literature, this investigation may serve as a pilot study and lay the foundation for future research.

The present investigation employed a randomized crossover design. The study was conducted in the Institute of Sport - National Research Institute in Warsaw, Poland, in July and August 2025. Across 2 consecutive days, the participants underwent two 2-hour sessions under hypoxia of 4200m asl (FiO2 = 12.8%) in a normobaric chamber (Air Sport, Międzyzdroje, Poland). The sessions were held at the same time of day, between 17:00 and 19:00. Temperature (approximately 21 °C), humidity (45-50%), and gas concentration were centrally controlled and maintained at stable levels throughout the exposure period. During the control session, the participants remained seated without any activity. During the experimental session, they additionally performed a 5-minute VIH session (20 breaths/minute) after 1 hour of hypoxic exposure. Isocapnic BreathWayBetter devices (Isocapnic Technologies Inc., Kelowna, British Columbia, Canada) equipped with 6-liter breathing bags were employed to perform VIH. The accompanying Isocapnic mobile app was used to guide breathing rhythm and monitor session duration. The order of sessions was determined using block randomization within subgroups of 4-6 individuals to ensure balanced exposure to each condition. Multiple measurements were taken, including blood pressure, heart rate, SpO2, blood gasometry, and the 2018 Lake Louise AMS Score.
Detailed Description: Blood gas analysis was conducted using a Radiometer™ ABL90 FLEX (Radiometer Medical ApS, Brønshøj, Denmark). The following parameters were assessed: hydrogen ion concentration (pH), bicarbonate ion concentration (HCO₃-), partial pressure of oxygen (pO₂), and partial pressure of carbon dioxide (pCO₂). All measurements were taken in duplicate using 45 µL capillary blood samples collected from the fingertip. Analyses were performed immediately following collection by a trained technician following the manufacturer's instructions.

Peripheral blood pressure was measured digitally using the OMRON M2 monitor (OMRON Healthcare, Kyoto, Japan).

SpO₂ was estimated at the fingertip using a pulse oximeter (NONIN Onyx Vantage 9590, Nonin Medical, Inc., Plymouth, MN, USA).

The 2018 Lake Louise AMS Score questionnaire was presented to the participants before the experiment for familiarization and then used to evaluate symptoms of AMS based on a combination of subjective self-reports and clinical findings.

All the measurements were performed by qualified and experienced specialists. The participants were blinded to the obtained results, except for the 2018 Lake Louise AMS Score, which was self-reported.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
102.39/2025 OTHER_GRANT Institute of Sport-National Research Institute, Poland View