Viewing Study NCT07206134


Ignite Creation Date: 2025-12-25 @ 2:22 AM
Ignite Modification Date: 2025-12-26 @ 12:54 AM
Study NCT ID: NCT07206134
Status: COMPLETED
Last Update Posted: 2025-10-03
First Post: 2025-09-12
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Evaluation of Modified Omega Plate in the Management of Mandibular Fractures Compared With Conventional Fixation
Sponsor: Tanta University
Organization:

Study Overview

Official Title: Modified Omega Bone Plate Versus Conventional Miniplates for Fixation of Mandibular Fractures in Mental Nerve Region
Status: COMPLETED
Status Verified Date: 2025-09
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: COMET-OMF
Brief Summary: Twelve adult patients with mandibular fractures in the mental region were enrolled and randomly divided into two equal groups. Group I received fixation using custom-designed modified omega bone plates, while Group II was treated with conventional titanium miniplates following Champy's technique. Virtual surgical planning and 3D printing technology were used to fabricate customized plates in Group I. Clinical and radiographic assessments were conducted immediately, at 1 week, 3 months, and 6 months postoperatively. Parameters evaluated included soft tissue healing, pain, facial edema, lower lip paresthesia, maximal mouth opening, occlusion, fracture stability, and hardware integrity.
Detailed Description: This study was conducted on twelve adult patients with mandibular fracture in mental nerve region, selected from the outpatient clinic, Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Tanta University.

The selected patients were randomly divided into two equal groups, group I (6 patients) were treated by modified omega bone plate, while group II (6 patients) were treated by 2.0 mm conventional miniplates according to Champy's principle. A comparison between the two groups was conducted.

Modified Omega bone plate is a specially-designed, 8-hole, titanium miniplate modified by adding upper struts to the Ω symbol. It has lower horizontal struts (which provides stability along the lower border) with four holes, the proximal 2 holes are round and the distal are pear shape (compression holes). Two vertical struts at the ends of the horizontal struts (which provide resistance against the torsional forces),Upper horizontal struts (which counteract the tensional forces along the alveolar border) with four holes the proximal 2 holes are round and the distal are pear shape. The omega shape of this plate helps it to adapt easily around the mental neurovascular bundle.

Preoperative evaluation of the patients was carried out by taking history and performing clinical and radiographic examinations. Clinical examination included intraoral and extraoral inspection and palpation of the fracture sites. Radiographic examination was used to determine the site, number, type of fractures and degree of displacement.

Under general anesthesia, the fracture line was exposed through an intraoral approach, and the fracture segments were reduced. In group I, fixation of the reduced segments was done with modified omega bone plate which predetermined virtually. In group II, 2conventional miniplates placed on inferior border \& subapical were used to fix the fracture.

Postoperative clinical evaluation were performed immediately, one week, two weeks, one month, three months and postoperative radiographic evaluation were performed immediately, three months and six months. The postoperative clinical evaluation included presence or absence of infection, bony union or stability, state of occlusion, maximal mouth opening, sensory nerve function, condition of teeth related to the fracture line and, patient's tolerance to the plate.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: