Viewing Study NCT02082834


Ignite Creation Date: 2025-12-25 @ 2:19 AM
Ignite Modification Date: 2026-02-05 @ 9:09 PM
Study NCT ID: NCT02082834
Status: COMPLETED
Last Update Posted: 2014-03-10
First Post: 2014-02-21
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: Post EVAR Endoleak Detection : Model-based Iterative Reconstruction (MBIR) vs Adaptive Statistical Iterative Reconstruction (ASIR) CTA; a Prospective Study
Sponsor: University Hospital, Clermont-Ferrand
Organization:

Study Overview

Official Title: Post EVAR Endoleak Detection : Model-based Iterative Reconstruction (MBIR) vs Adaptive Statistical Iterative Reconstruction (ASIR) CTA; a Prospective Study
Status: COMPLETED
Status Verified Date: 2014-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The purpose of the study is to compare the accuracy of the diagnosis of endoleak in patient with EVAR comparing Adaptive statistical iterative reconstruction (ASIR) CTA and Model-based iterative reconstruction (MBIR- VEO TM).
Detailed Description: Background:

The aortic aneurysm is a common and serious disease share its complications (rupture ) , often fatal. It is recognized that pass a certain diameter surgical or endovascular treatment reduces mortality by avoiding treatment in extreme provider of high morbidity and mortality emergency. Endovascular anevrysm repair (EVAR) treatment has proven effective but unfortunately this treatment presents complications ( endoleak ) should be sought systematically by repeated checks CT . The irradiation in these patients is a major problem with repeated exposure radiation. The follow up of these patients requires repeated CT because endoleaks can be delayed.

Iterative reconstruction of previous generation have reduced the dose , we dispose the last Model-based iterative reconstruction (" VEO " ) for a further reduction of patient dose . This technique has not yet been evaluated in the detection of endoleaks.

The purpose of the study is to compare conventional CTA (ASIR50) ( gold standard now) with Model-based iterative reconstruction (MBIR- VEO TM) in the detection ( and classification ) of endoleaks in patients traited by EVAR.

All patient admited in Radiology to follow up his EVAR is included in the study and receive both CT: Adaptive statistical iterative reconstruction (ASIR) CTA and Model-based iterative reconstruction (MBIR- VEO TM) and the result of thoses 2 CT are compared by 2 readers (blinded of the result) The BMI , other complications, the DLP , dose reduction and quality of the examination is noted .

Study Oversight

Has Oversight DMC:
Is a FDA Regulated Drug?:
Is a FDA Regulated Device?:
Is an Unapproved Device?:
Is a PPSD?:
Is a US Export?:
Is an FDA AA801 Violation?: