Viewing Study NCT05804760


Ignite Creation Date: 2025-12-25 @ 2:15 AM
Ignite Modification Date: 2025-12-26 @ 12:44 AM
Study NCT ID: NCT05804760
Status: COMPLETED
Last Update Posted: 2023-04-07
First Post: 2023-03-27
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Predictive Value of Reduced Keratinized Mucosa on the Secondary Prevention of Peri-implant Mucositis and Periimplantitis in Patients Attending Regular Supportive Peri-implant Care. A Longitudinal Analysis
Sponsor: Hannover Medical School
Organization:

Study Overview

Official Title: Predictive Value of Reduced Keratinized Mucosa on the Secondary Prevention of Peri-implant Mucositis and Periimplantitis in Patients Attending Regular Supportive Peri-implant Care. A Longitudinal Analysis
Status: COMPLETED
Status Verified Date: 2023-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: * Capture of the potential risk factor "lack of band of keratinised mucosa" over a period of up to 5 years.
* Recording of peri-implant inflammatory processes in study participants that are not recorded during normal tooth cleaning
* Registration of the extent of radiographic bone loss. Bone resorption through analysis of existing X-ray images
* Individual therapy recommendation/individual supportive peri-implant care in case of peri-implant inflammation
* The present study was specifically designed to investigate the effect of reduced width of keratinized mucosa (KM) on the secondary prevention of peri-implant mucositis and peri-implantitis in patients attending a supportive peri-implant care program (SPIC) over an observation period of up to five years.
Detailed Description: Patient information such as age, gender, history of periodontitis, edentulism, previous oral and maxillofacial tumor with a history of head and neck radiation, smoking habits, and metabolic diseases like diabetes mellitus were collected. Implant-specific information such as bone augmentation, year of implantation, implant position, implant level (bone level, tissue level), and number of implants were also documented. Prosthetic factors like the type of prosthesis (single crown, bridge construction, telescope prosthesis) and the type of attachment (cemented, screwed) were recorded. Clinical examination and measurement of clinical parameters were subsequently performed, including probing depth (PD) at six implant sites using a graduated periodontal probe, bleeding on probing or suppuration (BoP/Sup) occurring within 30 seconds after probing, and recessions measured in mm using a graduated periodontal probe between a defined clinical reference point and the implant mucosa.Participants were motivated to undergo regular SPIC, with frequency based on their individual risk factors. Patients without increased risk were encouraged to attend a 6-month recall. If bleeding or suppuration occurred, the frequency of SPIC was increased to monthly controls with oral hygiene instruction and plaque removal. Peri-implantitis therapy was initiated in patients with radiographically detectable bone loss, followed by lifelong SPIC. The modified plaque index (mPl) and full mouth plaque score API were used to assess local plaque accumulation and compliance. The modified gingival index (mGI) was used to assess the inflammatory state of the soft tissue. The mucositis severity score (MSS) was used to investigate the initiation and progression of peri-implant mucositis, with scores ≥18 indicating advanced inflammation. KM impact on MSS values \<8 and ≥18 was investigated. Periodontal screening index (PSI) was used to classify the general periodontal condition of the patients by dividing the dentition into sextants. The width of the KM mucogingival junction was assessed using the "rolling technique." Radiographs were analyzed using byzznxt to diagnose possible radiological bone resorption. An individual diagnosis was made for each implant at the end of the examination, and data was collected following a standardized operating procedure and saved electronically.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: