Viewing Study NCT00443560


Ignite Creation Date: 2025-12-25 @ 2:15 AM
Ignite Modification Date: 2025-12-31 @ 2:36 PM
Study NCT ID: NCT00443560
Status: COMPLETED
Last Update Posted: 2014-04-14
First Post: 2007-03-02
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: The Association Between Decreasing Labor Analgesia Epidural Infusion and Forceps Delivery
Sponsor: Northwestern University
Organization:

Study Overview

Official Title: A Retrospective Case-controlled Study of the Association Between Request to Discontinue Second Stage Labor Epidural Analgesia and Risk of Instrumental Vaginal Delivery
Status: COMPLETED
Status Verified Date: 2014-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The objective of this study will be to compare epidural infusion management, specifically looking at infusion rate changes, in patients who receive forceps deliveries versus normal spontaneous vaginal deliveries. We will match patients based on time and date of delivery, as well as parity, in order to eliminate these variables as potential con-founders.

We hypothesize patients who require a decrease in their basal labor analgesia epidural infusion rate will have an increased incidence of forceps delivery.
Detailed Description: The obstetrical anesthesia database will be queried for all forceps deliveries between the dates of January 2004-October 2005. To minimize the influence of different anesthetic and obstetric care providers, the control group consisted of parturients who has spontaneous vaginal deliveries (SVD) in the same 24 hour period who were case-matched for gravidity and parity. Parturients with twin deliveries and fetal demise were not selected for either group.

The database will be queried for the following: maternal age, parity, gestational age, type of analgesia, changes in epidural infusion rate and/or concentration, and supplemental bolus doses of local anesthesia. The data will be stripped of identification by the database manager and entered into a secured computer which is password protected and maintained in the Department of Anesthesiology. The primary endpoint is to evaluate if decreasing the epidural infusion rate was associated with a forceps delivery.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: