Viewing Study NCT00491660


Ignite Creation Date: 2025-12-25 @ 2:08 AM
Ignite Modification Date: 2026-04-12 @ 12:27 PM
Study NCT ID: NCT00491660
Status: COMPLETED
Last Update Posted: 2007-06-26
First Post: 2007-06-25
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: Effect of Gravity on Tracheal Colonization During Mechanical Ventilation in Infants
Sponsor: Cairo University
Organization:

Study Overview

Official Title: None
Status: COMPLETED
Status Verified Date: 2007-06
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Ventilator-associated pneumonia (VAP) is the leading cause of death among all nosocomial infections in ventilated patients. Once intubated, the risk of pneumonia in hospitalized patients is increased 3-10 fold; almost 90% of hospital-acquired pneumonia occurs in intubated patients. Each episode of VAP is associated with 7-9 days of additional hospital stay with an estimated increase in cost of care that exceeds $40,000. In an effort to control VAP, several studies were conducted including oral and gastric decontamination with antibiotics, rotation of the bed, and local instillation of antibiotics via endotracheal tube. Despite such efforts, VAP is still a major complication for intubated patients.

The effect of gravity on bacterial colonization of the endotracheal tube was recently explored in an animal study that was conducted at the United States National Institutes of Health. The study demonstrated a significantly lower tracheal colonization and decreased alveolar contamination in ventilated sheep when positioned on their side allowing for tracheal drainage by gravity. Such findings have not been validated in clinical practice and the need for clinical trials studying the effect of lateral positioning have been demanded. Therefore, we aimed our randomized controlled trial to test the hypothesis that intubated infants who are positioned on their side are at lower risk for contracting microbes in their trachea when compared to those in a supine position.
Detailed Description: Subjects were to be randomly assigned to one of two groups:

1. Supine group, in which infants are maintained on their back at all times. The endotracheal tube is held upright in vertical position at all times. The bed is kept horizontal without any angle or tilt.
2. Lateral group. Infants are maintained on their side while the back supported with a rolled towel. The endotracheal tube is maintained to rest horizontally on the bed.

Study Oversight

Has Oversight DMC:
Is a FDA Regulated Drug?:
Is a FDA Regulated Device?:
Is an Unapproved Device?:
Is a PPSD?:
Is a US Export?:
Is an FDA AA801 Violation?: