Viewing Study NCT04938960


Ignite Creation Date: 2025-12-25 @ 2:07 AM
Ignite Modification Date: 2025-12-26 @ 12:33 AM
Study NCT ID: NCT04938960
Status: COMPLETED
Last Update Posted: 2025-05-06
First Post: 2021-06-22
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Identification of Non-gal, Non-HLA Antigens in Patients Implanted With Xenogenic Material
Sponsor: Mayo Clinic
Organization:

Study Overview

Official Title: Identification of Non-gal, Non-HLA Antigens in Patients Implanted With Xenogenic Material
Status: COMPLETED
Status Verified Date: 2025-05
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This study involves collecting serum samples from patients presenting for aortic valve replacement at Mayo Clinic, Rochester, MN. Serum samples will be collected pre-op, between 2 weeks and 3 months, between 3-11 months (optional), and between 12-18 months post-operatively. The patients antibodies in these serum samples will be used to capture proteins from the same type of tissue their replacement heart valves are made from (i.e., bovine/porcine pericardium - a non-human tissue which is currently used to make glutaraldehyde-fixed heart valves). The captured proteins will be identified, and compared over time (i.e., 0, 1, 3 and 12 months) to determine which proteins (i.e., antigens) in bovine/porcine pericardium that the patient is mounting an immune response towards.
Detailed Description: Protein G HP SpinTrap columns will be used to capture IgG antibodies from patient serum pre-implant, between 2 weeks-3 months, between 3-11 months and between 12-18 months post-implant. These antibodies will be cross-linked to the column and then protein extracted from implant tissue (ie Native bovine/porcine pericardium) will be deglycosylated and run through the column. Antigenic proteins will be trapped and non-antigenic proteins will be washed through the column. These antigenic proteins will be eluted off the column and identified using LC-MS/MS. The proteins identified in the pre-implant elutant will be compared to the proteins in post-implant elutant to identify xenoantigens. Success criteria will be method validation by identification of previously known and new currently unknown xenoantigens.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: False
Is an FDA AA801 Violation?: