Viewing Study NCT06053060


Ignite Creation Date: 2025-12-25 @ 2:05 AM
Ignite Modification Date: 2025-12-26 @ 5:52 AM
Study NCT ID: NCT06053060
Status: COMPLETED
Last Update Posted: 2023-09-25
First Post: 2023-03-24
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Evaluation of the Positioning of the Dynacup Cup "One C" Versus "Standard Dynacup"
Sponsor: Groupe Hospitalier Diaconesses Croix Saint-Simon
Organization:

Study Overview

Official Title: Evaluation of the Positioning of the Dynacup Cup "One C" Versus Standard Dynacup
Status: COMPLETED
Status Verified Date: 2023-09
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: DYNACUP
Brief Summary: The ceramic-ceramic friction pair is widely used today in total hip arthroplasty, including fourth-generation ceramics which show the lowest wear rate. These have considerably reduced the risk of head fracture compared to previous generations; however, the risk of insert rupture persists with rates similar to those of third generation ceramics.

These ceramic fractures require complex revision surgery, which brings complications, exposing patients to the risk of third-body wear and tear related to persistent post-surgical debris. They are frequently due to an incorrect assembly of the ceramic causing intraoperative or early postoperative rupture. To fix this, manufacturers have developed pre-assembled cups in the factory. The Dynacup One C cup developed by CorinĀ® corresponds to the pre-assembled version of the Dynacup cup, making it possible to eliminate the risk of anomaly during intraoperative assembly linked to the human factor and to offer patients with very small cups an adapted ceramic implant. A single study with a small sample compared the two implants (pre-assembled version \[vs\] modular version) clinically, radiologically and functionally without showing any significant difference. The lack of data in the literature comparing these two implants motivated us to conduct a randomized comparative study on a large sample of patients.
Detailed Description: Patients eligible for a total hip arthroplasty with a ceramic-ceramic friction couple and scheduled for surgery will be included in this study after information and collection of written consent.

After randomization, a preoperative radiograph with a calibration ball will be taken to plan the prosthesis and identify the characteristics of the operated hip.

An x-ray of the pelvis with a 28 mm ball will be carried out the day after the intervention according to the same preoperative procedures in order to measure the postoperative radiographic parameters.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: