Viewing Study NCT05877794


Ignite Creation Date: 2025-12-25 @ 1:45 AM
Ignite Modification Date: 2025-12-26 @ 1:13 AM
Study NCT ID: NCT05877794
Status: UNKNOWN
Last Update Posted: 2023-05-26
First Post: 2022-06-17
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Does the Central Venous Puncture Needle Need to be 7 cm?
Sponsor: Ajou University School of Medicine
Organization:

Study Overview

Official Title: Does the Central Venous Puncture Needle Need to be 7 cm? ; Safety and Usefulness of Needle Length Adjustment Method Using Suture Wing
Status: UNKNOWN
Status Verified Date: 2023-05
Last Known Status: NOT_YET_RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The central venous catheter (CVC) has been used for the first time in clinical use in 1921 and has been used worldwide by 2023. Although there are differences between studies, it is reported that side effects occur in approximately 5-20% of patients undergoing CVC. Common side effects include hematoma, venous puncture, arterial puncture, and pneumothorax, and horner syndrome is also reported in 5% of cases. In particular, in the case of the internal jugular vein (IJV), the possibility of puncture of the internal carotid artery is higher than that of other sites, and the puncture level also varies depending on the depth of needle insertion, which in some cases can cause very serious side effects. The incidence rate of side effects depends on the method of inserting the CVC and the skill of the operator. Previous method approached the IJV using the anatomy ladmark with the blind Seldinger technique, recently, as the use of ultrasound has become more common.

Ultra sound guided CVC insertion tecnique reduce the incidence of side effect. However, there are still major complications exist because less experiance operator inserts needle too deep without caution and only depends on the image of sonography.

Currently, the length of the needle commonly used in the CVC catheter set is 7 cm. In general, the depth from the skin to the IJV is within 1.5cm on either the right or the left, and under the premise that the needle insertion angle is 45 degrees, the distance from the skin to the IJV is within 2cm. Based on this, in previous studies, it was announced that the length of the needle required for IJV access was less than 4 cm.

The purpose of this study is to study the usefulness and safety of the method of sono-guided CVC catheter insertion by fixing the needle at a position 4 cm from the needle tip by placing the suture wing (18G, single catheter set).
Detailed Description: None

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: