Brief Title: Effect of Targeting Left Ventricular Lead Position on the Rate of Response to Cardiac Resynchronization Therapy.
Sponsor: University of Calgary
Organization:

Study Overview

Official Title: Investigating Non-response to Cardiac Resynchronization: Evaluation of Methods to Eliminate Non-response & Target Appropriate Lead Location (INCREMENTAL).
Status: COMPLETED
Status Verified Date: 2015-11
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: INCREMENTAL
Brief Summary: Identifying \& optimizing strategies to reduce the burden of heart failure is vital. Despite advances in pharmacotherapy, patients with heart failure are at high risk for death \& hospitalization. Cardiac resynchronization therapy (CRT) synchronizes ventricular mechanical activity, improves cardiac output \& reduces HF symptoms. However, \~50% of patients do not clearly respond to CRT. Sub-optimal placement of the LV pacing lead appears to be an important reason for non-response.

This study will assess whether targeted LV lead placement will result in an increased probability of CRT response at 52 weeks vs. usual (lateral wall) lead placement.
Detailed Description: Background. Identifying \& optimizing strategies to reduce the burden of heart failure (HF) is vital. Despite advances in pharmacotherapy, patients with HF are at high risk for death \& hospitalization. Over 25% of patients with systolic HF have dyssynchronous ventricular contraction that results in paradoxical septal motion, further impairing left ventricular (LV) function \& HF progression. Cardiac resynchronization therapy (CRT) synchronizes ventricular mechanical activity, improves cardiac output \& reduces HF symptoms. However, \~50% of patients do not clearly respond to CRT. Sub-optimal placement of the LV pacing lead appears to be an important reason for non-response.

Screening. Mechanical synchrony is vitally important in optimizing CRT response. Patients will be pre-screened with echocardiograms (echo) \& CRT provided to only those with dyssynchrony. The predicted rate of CRT response in patients pre-screened for dyssynchrony is estimated at 65%.

CRT response. The combined use of a valid \& simple measure of functional capacity with a reproducible measure of LV volume is optimal in identifying CRT responders. These outcomes will be assessed using the Specific Activity Scale \& radionuclide angiography (RNA), respectively.

Primary hypothesis. Targeted LV lead placement will result in an increased probability of CRT response at 52 weeks vs. usual (lateral wall) lead placement. CRT response will be defined as ≥ 10% relative reduction in LV end systolic volume \& ≥ 1 Specific Activity Scale class improvement.