Other Event

Other Event

Other Adverse Events are non-serious adverse events that exceed a specific frequency threshold (typically 5% within any study arm). These events are reported to provide comprehensive safety information about all noteworthy adverse occurrences during clinical trials. Each other event is categorized by term, organ system, assessment type, and source vocabulary for standardized reporting.

Other Event path is as follows:

Study -> Results Section -> Adverse Events Module -> Other Event

Study -> Results Section -> Adverse Events Module -> Other Event -> Other Event Stats

Other Event


Ignite Creation Date: 2025-12-24 @ 4:23 PM
Ignite Modification Date: 2025-12-25 @ 2:18 PM
NCT ID: NCT02213666
Term: Oropharyngeal bleeding from TEE
Organ System: Surgical and medical procedures
Assessment Type: SYSTEMATIC_ASSESSMENT
Source Vocabulary: None
Notes: 2 patients developed oropharyngeal bleeding from the TEE probe - this is a known complication associated with TEE imaging and not associated with participation in the study. This resolved spontaneously without further consequence or intervention.
Study: NCT02213666
Study Brief: Comparison of Intracardiac Echocardiography and Transesophageal Echocardiography
Other Event Stats (If Any):

Other Event Stats

Group ID # Events # Affected # At Risk View
EG000 2 2 71 View