Event Group

Event Group

Event Groups are part of the Adverse Events Module within the Results Section. They provide a way to organize and summarize adverse event data by grouping related events together.

Each Event Group typically represents a category or class of adverse events and includes statistical information such as the number of participants affected and at risk for different event types: deaths, serious events, and other events.

Event Group path is as follows:

Study -> Results Section -> Adverse Events Module -> Event Group

Event Group


Ignite Creation Date: 2025-12-24 @ 4:08 PM
Ignite Modification Date: 2025-12-25 @ 2:08 PM
NCT ID: NCT05359666
Group ID: EG000
Title: Irrisept
Description: IrriseptĀ® was used for surgical irrigation in subjects with abdominal trauma or acute surgical abdomen for study protocol IRR-CT-901-2013-01. Irrisept: IrriseptĀ® is a manual, self-contained irrigation device designed for wound cleansing and irrigation. The solution is 0.05% Chlorhexidine Gluconate (CHG) in sterile water for irrigation, USP (99.95%). Irrisept contents include the solution, a 450 mL bottle, and the Irriprobe applicator. Irrisept is a manual, self-contained irrigation device that can produce 7-8 psi of pressure for effective wound cleansing and irrigation. The user squeezes the bottle to create streams of solution and directs the fluid from the applicator onto a wound. The mechanical action of the streams of fluid being applied over a wound removes particulates and debris. Subjects randomized to Irrisept on study protocol IRR-CT-901-2013-01 used the device, per the provided Instructions for Use.
Deaths Number Affected: 7
Deaths Number At Risk: None
Serious Number Affected: 63
Serious Number At Risk: 294
Other Number Affected: 157
Other Number At Risk: 294
Study: NCT05359666
Results Section: NCT05359666
Adverse Events Module: NCT05359666