The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 12:39 AM
Ignite Modification Date: 2025-12-25 @ 12:39 AM
NCT ID: NCT06216067
Brief Summary: The goal of this clinical trial is to evaluate two separate operating room cataract measuring tools in predicting the residual astigmatism (prediction error) in patients with corneal astigmatism. The main question it aims to answer is: Show the refractive predictability comparing the use of Operating Room cataract toric lens placement tools against the standard manual technique. Participants will be implanted with the TECNIS Toric II IOL Lens Model ZCU; the second eye, if applicable, is to be implanted within 45 days of the first-eye surgery. Researchers will compare two Operating Room cataract lens placement tools: the Zeiss CALLISTO vs. the Wavetec AnalyzOR to determine refractive predictability.
Detailed Description: To evaluate two separate operating room cataract measuring tools in predicting the residual astigmatism (prediction error) in patients with corneal astigmatism (maximum allowable up to 3.0D) comparing the ZEISS CALLISTO eye and the Wavetec AnalyzOR at the one-month post-operative visit. Both surgery rooms will be using Veracity, IOL Master and Zeiss Opmi Lumera i Operating Room Microscopes. Operating Room #1 will be utilizing the ZEISS CALLISTO eye for axis alignment, along with Veracity and IOL Master for lens selection, and Operating Room #2 will be utilizing the Wavetec AnalyzOR for lens selection and axis alignment. Procedure times for the ZEISS CALLISTO eye and the Wavetec AnalyzOR will be obtained by using a start/stop watch, including phakic power calculation and toric positioning. In addition, the suction on (start of LenSx), treatment time of LenSx in seconds, suction off (end of LenSx), start time of primary incision, the beginning of Phaco, end of phaco, CDE (Combined Diffused Energy) total and the end time of procedure will all be documented. All times will be analyzed and compared between Operating Room #1 and Operating Room #2.
Study: NCT06216067
Study Brief:
Protocol Section: NCT06216067