Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 12:13 AM
Ignite Modification Date: 2025-12-25 @ 12:13 AM
NCT ID: NCT04539158
Brief Summary: Currently, the usual initial strategy for direct current cardioversion (DCCV) typically involves delivering 200J of electricity between two pads placed in the anterior and posterior positions (i.e., one on the chest and one on the back). However, this technique may be less likely to result in successful cardioversion in obese patients (BMI ≥30 kg/m2). Failure to achieve sinus rhythm then necessitates additional shocks, which still may ultimately fail to terminate the patient's atrial fibrillation, thereby increasing the likelihood of adverse events from multiple cardioversion attempts "Dual-DCCV" is a technique in which four pads are used to deliver two simultaneous shocks of 200J, totaling 400J. Guidelines published by the American Heart Association/American College of Cardiology/Heart Rhythm Society and the European Society of Cardiology provide only general guidance regarding the appropriate technique and energy selection in patients undergoing cardioversion, with no specific recommendations pertaining to dual-DCCV or obese patients. This study aims to assess the safety and efficacy of dual-DCCV as an initial treatment strategy, compared to standard single-DCCV, in the obese population.
Detailed Description: Patients with sustained atrial fibrillation and obesity who are scheduled for a cardioversion for atrial fibrillation will provide written informed consent prior to starting the procedure. Patients will be randomly assigned in a 1:1 fashion to either single-DCCV or dual-DCCV treatment. All patients will have 4 defibrillation pads placed: two pads placed in the right infraclavicular region and left flank region, plus two pads placed in the left infraclavicular and right flank region. All patients will receive moderate sedation immediately prior to and during cardioversion. Patients randomized to single-DCCV will be given a single 200J shock using the "primary" (or right anterior-left posterior) pair of pads. Patients assigned to dual-DCCV will receive two simultaneous 200J shocks (from both the "primary" and "secondary" set of defibrillator pads), totaling 400J delivered. Patients in the single-DCCV group whose initial shock fails to restore normal sinus rhythm will be crossed over to the dual-DCCV group. Patients in the dual-DCCV group will receive up to three attempts at DCCV, as needed, at the discretion of the attending electrophysiologist. One hour after cardioversion is completed, patients will be asked if they experienced any chest discomfort related to cardioversion and, if applicable, will rate their chest discomfort using a pain scale from 0-10.
Study: NCT04539158
Study Brief:
Protocol Section: NCT04539158