Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 12:13 AM
Ignite Modification Date: 2025-12-25 @ 12:13 AM
NCT ID: NCT04541758
Brief Summary: Open, randomized, parallel controlled prospective clinical study design was used in this study.Subjects were patients with 2-4 displaced non-flail rib fractures.Operation group (Group 1) : minimally invasive internal fixation operation group under spontaneous breathing anesthesia.In the operation group of minimally invasive internal fixation under autonomic respiratory anesthesia, the fracture was determined preoperatively by chest CT+ three-dimensional reconstruction of the ribs, and the optimal incision location was determined. The fracture was exposed through as many small incisions as possible, and fixed with titanium plate or clon-type plate. During the operation, the autonomic respiratory anesthesia and paraviral nerve block technology was adopted.In the conservative group (group 2), routine treatment measures such as analgesia and chest strap fixed were adopted.The purpose of this study was to evaluate the safety, feasibility, and efficacy of minimally invasive and conservative treatment for rib fractures with different Numbers of displaced ends.
Detailed Description: An open, randomized, parallel controlled prospective clinical study design type was used in this study. Subjects were patients with two to four displaced non-flail chest fractures of the ribs. Operation group (Group 1) : minimally invasive internal fixation operation group under spontaneous breathing anesthesia. In the operation group of minimally invasive internal fixation under autonomic respiratory anesthesia, the fracture was determined preoperatively by chest CT+ three-dimensional reconstruction of the ribs, and the optimal incision location was determined. The fracture was exposed through as many small incisions as possible, and fixed with titanium plate or clon-type plate. During the operation, the autonomic respiratory anesthesia and paraviral nerve block technology was adopted. In the conservative group (group 2), routine treatment measures such as analgesia, hemostasis and chest band fixation were adopted. The effects of the two treatments on lung function, pain index, complications and QoL were evaluated. It provides theoretical basis for the treatment of rib fracture
Study: NCT04541758
Study Brief:
Protocol Section: NCT04541758