Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 11:52 PM
Ignite Modification Date: 2025-12-24 @ 11:52 PM
NCT ID: NCT06227351
Brief Summary: The aim of study is evaluation of accuracy of completely versus partially limiting computer generated surgical three-dimensional guides during placement of zygoma implants in patients with atrophic maxillae.
Detailed Description: According to World Oral Health Organization (WHO), losing teeth and arch edentulism is the result of a life long history of oral diseases like advanced dental caries and severe periodontal disease. Complete tooth loss estimated global average prevalence is 7% among people aged 20 years and 23% among people aged 60 years or older. Tooth loss lead to bone resorption in all direction. Non-grafting solutions have been developed to reduce risks, morbidity, and treatment time. These types of treatment are often preferred by patients, considering that they may minimize total treatment time and have less morbidity than staged procedures of grafting solutions.One of non-grafting solutions is the zygomatic implants. Zygomatic implants have shown improved clinical results compared with bone grafting in compromised maxillary bone.But the same as any surgical procedure, placing zygomatic implants has potential complication, such as: oro-antral communication, paresthesia or altered sensation of the infra orbital nerve also penetration of the orbital cavity may occur. In order to achieve the optimal position of zygomatic implant, computer-based planning has been introduced with the use of surgical guides. Surgical guides are classified according to design concepts for fabrication of surgical guide to non-limiting, partially limiting design and complete limiting. In partially limiting design,the first drill is used then the surgical guide is removed and the osteotomy and implant placement are completed in freehand while in complete limiting design all the instruments used in surgical procedure during implant placement are restricted. In literature, there is low evidence of using partially guided surgery for zygomatic implant and also of comparing the two designs with each other. the aim of study is evaluation of accuracy of completely versus partially limiting computer generated surgical three-dimensional guides during placement of zygoma implants in patients with atrophic maxillae.
Study: NCT06227351
Study Brief:
Protocol Section: NCT06227351