The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 11:39 PM
Ignite Modification Date: 2025-12-24 @ 11:39 PM
NCT ID: NCT06033651
Brief Summary: Patients are to be approached to attend clinic who have been identified as being implanted with either a Lima Corporate Delta Revision TT, Delta One TT or the Delta Multihole Systems hip systems between 2011 and 2015, a minimum of 10 years since hip surgery. They will be x-rayed (AP pelvis and a lateral view) and have a clinical review in clinic.
Detailed Description: Since its popularisation in the 1960's, Hip replacements have become one of the NHS's highest volume procedures. Unfortunately, hip replacements can fail with on average 8,500 revision hip replacements being performed each year pre-covid(1). Often this is very complex with destruction of the normal anatomy leaving surgeons with a significant challenge in ensuring appropriate positioning of the socket within the confines of the patient's anatomy. The Lima Corporate Delta systems are designed to help surgeons with this very problem by providing the option of a 'face changer' allowing surgeons to place a socket within a socket. To allow for this function, the 'face changer' must connect with the acetabular cup (socket). 140 patients have been identified as having had this modular acetabular system implanted at the RJAH in 2012 \& 2014, going into 2015. The aim of this study is to therefore identify the survivorship of these implants at 10 years.
Study: NCT06033651
Study Brief:
Protocol Section: NCT06033651