Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-26 @ 1:19 PM
Ignite Modification Date: 2025-12-26 @ 1:19 PM
NCT ID: NCT06816706
Brief Summary: Spontaneous breathing trials (SBT) are essential for assessing extubation tolerance, yet optimal approaches are debated. High-flow nasal oxygen offers benefits like precise oxygen delivery, flow-related positive end-expiratory pressure generation and improved lung function. While high-flow tracheal oxygen can also be used as an SBT method, it has reduced physiological effects due to bypassing the upper airway with a more open circuit. To enhance this limitation, investigators developed a modified high-flow tracheal oxygen tube with a smaller expiratory end diameter to increase expiratory resistance and airway pressure. This is a prospective randomized crossover study that aims to compare the physiological effects of standard and modified high-flow tracheal oxygen versus T-piece during SBT.
Detailed Description: A spontaneous breathing trial (SBT) is a crucial step in the weaning and extubation process for assessing extubation tolerance. However, the optimal approach for conducting SBTs remains a topic of debate. High-flow nasal oxygen has been shown to provide several physiological benefits, including precise control of the fraction of inspired oxygen, generation of flow-related positive end-expiratory pressure, increased end-expiratory lung volume, improved oxygenation, and enhanced carbon dioxide elimination. High-flow oxygen therapy can also be applied via an artificial airway as high-flow tracheal oxygen. Previous studies have identified this therapy as a potential alternative for SBTs. However, compared to high-flow nasal oxygen, high-flow tracheal oxygen exhibits significantly diminished physiological effects due to the bypassing of the narrow nasopharynx, glottis, and upper airway as well as a more open circuit. To address this limitation, the investigators have developed a modified high-flow tracheal oxygen tube with a reduced expiratory end tube diameter. This modification aims to create higher expiratory resistance and airway pressure, thereby simulating the physiological effects of HFNC. This study is a prospective randomized crossover physiological study designed to compare the effects of standard and modified high-flow tracheal oxygen versus T-piece during spontaneous breathing trials. Key physiological parameters will be assessed, including airway pressure, end-expiratory lung volume, vital signs, oxygenation, and respiratory workload.
Study: NCT06816706
Study Brief:
Protocol Section: NCT06816706