Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-26 @ 11:08 AM
Ignite Modification Date: 2025-12-26 @ 11:08 AM
NCT ID: NCT04633512
Brief Summary: ActivSightTM combines an innovative form factor and proprietary software to deliver precise, objective, real-time visualization of blood flow and tissue perfusion intraoperatively for laparoscope-based surgery. A small adaptor that fits between any existing laparoscope and camera systems and a separate light source placed along any current commercial system will deliver objective real-time tissue perfusion and blood flow information intraoperatively. Primary Objective: To determine safety and feasibility of ActivSightTM in displaying tissue perfusion in intestinal anastomoses including colorectal and bariatric surgery. Secondary Objective: To determine the efficacy of ActivSightTM in; (1) displaying tissue vascularity and perfusion in comparison to indocyanine green (ICG) during gastrointestinal anastomoses; and (2) displaying biliary tree during laparoscopic cholecystectomy using ICG-based intraoperative cholangiography (IOC).
Detailed Description: Design: * This is a feasibility study designed to evaluate safety and feasibility of ActivSightTM in gastrointestinal anastomoses and cholecystectomy. * Safety will be determined through clinical assessments and evaluation of any adverse event. * Feasibility will be determined through technically successful completion of intended visualization. * Assessment of preliminary efficacy will be performed through analysis of any intraoperative decisions made based on visual display as compared to standard endoscopic approach, or non-inferiority to ICG-based visualization and usability. * Patients outcome and follow up to Postoperative day 28 will be monitored for clinical outcome. * Target enrollment for the assessment of 80 patients; 52 evaluating intestinal anastomoses cases (including bariatric and colorectal cases); and 28 evaluating laparoscopic cholecystectomy. Stopping rules are triggered following the first 6 patients and a comparison group 6 patients in ICG-based treatment.
Study: NCT04633512
Study Brief:
Protocol Section: NCT04633512