The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 10:32 PM
Ignite Modification Date: 2025-12-24 @ 10:32 PM
NCT ID: NCT00685035
Brief Summary: Our primary hypothesis is that airway clearance therapy with sine waveform HFCWO using higher inflation pressures combined with both low and high oscillator frequencies will result in greater sputum production compared to sine waveform HFCWO with lower inflation pressures and mid-frequency oscillations.
Detailed Description: Patients with cystic fibrosis (CF) perform daily airway clearance therapy to facilitate removal of secretions from their airways. Many different techniques are available to achieve this and there is currently no consensus as to which form of therapy is most effective. High frequency chest wall oscillation (HFCWO) is used by CF patients throughout the United States and abroad. To perform this therapy, the patient wears a vest which fits over the entire torso and is connected to an air compressor. The compressor generates oscillating air pulses that are transmitted to the lungs, thereby mobilizing secretions. The most commonly used device is The Vestâ„¢ Airway Clearance System, (Hill-Rom Inc, St Paul, MN). Adjustment of the inflation pressure and frequency of oscillations affects the volume of displaced air and flow of air measured at the mouth of the patient. Previous studies indicate this form of therapy is as effective as more traditional and cumbersome forms of therapy. However, it is unclear which inflation pressures and oscillator frequencies provide optimal airway clearance. Some studies of sine waveform HFCWO reported the largest volume of air displacement and highest air flow measured at the mouth when using a combination of high inflation pressures with either low (7 - 10 Hz) or high frequencies (18 - 20 Hz), but most CF centers in the United States use HFCWO with lower pressures combined with mid-range frequencies (10 - 14 Hz). Furthermore, there are no previous studies assessing the affect of sine waveform HFCWO settings on sputum production. As a result, there is no consensus on which pressure and frequency settings are most efficacious for CF patients.
Study: NCT00685035
Study Brief:
Protocol Section: NCT00685035