Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 10:29 PM
Ignite Modification Date: 2025-12-24 @ 10:29 PM
NCT ID: NCT04981535
Brief Summary: According to preexisting data, it has revealed the fundamental role that aerosols play in the transmission of the COVID-19 virus. Esophagogastroduodenoscopy (EGD), producing particle smaller than 5 microns, was regarded as 'aerosol-generating procedures' (AGPs) associated with an increased risk of transmission of respiratory pathogens to healthcare workers. The strategies aim to reduce spreading of aerosol during the procedure should be beneficial. Using an acrylic box to cover the head of a patient undergoing an endoscopy seems to reduce aerosol scatter and reduce the spread of respiratory pathogens. At present, there are no high-quality studies that provide quantitative data on the use of head box to reduce aerosol generation.
Detailed Description: Pandemic of coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) affected globally clinical practice including temporary postponement of elective endoscopic procedures in GI office activity and has caused an unprecedent concern in personal protection against the airborne virus. Whitin 2.5 years since the outbreak in mid-December 2019, COVID-19 had infected over 182 million people and killed more than 3.9 million across 210 countries worldwide. (Ref. https://www.who.int/emergencies/diseases/novel-coronavirus-2019). According to preexisting data, it has revealed the fundamental role that aerosols play in the transmission of the COVID-19 virus. Previously, in the medical community attempted to find strategies to minimize risk of respiratory transmission to HCPs during pandemic such as wearing either standard or full personal protective equipment (PPE), including do-it-yourself devices and gadgets are the necessary substitutes to protect them from aerosolization. However, there has been no published study evaluating the efficacy or real benefit of these tools in preventing aerosolization during EGD quantitatively. Esophagogastroduodenoscopy (EGD), producing particle smaller than 5 microns, was regarded as 'aerosol-generating procedures' (AGPs) associated with an increased risk of transmission of respiratory pathogens to healthcare workers. The strategies aim to reduce spreading of aerosol during the procedure should be beneficial. Using an acrylic box to cover the head of a patient undergoing an endoscopy seems to reduce aerosol scatter and reduce the spread of respiratory pathogens. At present, there are no high-quality studies that provide quantitative data on the use of head box to reduce aerosol generation.
Study: NCT04981535
Study Brief:
Protocol Section: NCT04981535