The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 6:37 PM
Ignite Modification Date: 2025-12-24 @ 6:37 PM
NCT ID: NCT03505957
Brief Summary: SafeBreak Vascular is a medical device indicated for fluid flow control during the administration of IV fluids/medication to the patient's vascular system and to aid in the prevention of unintended disruption and dislodgment of IVs. SafeBreak Vascular may be used for any hospitalized patient with gravity tubing or IV pumps, for intermittent infusion or continuous infusion.The primary objective of this study is to determine if the delivery of IV medications and/or fluids with SafeBreak Vascular functions with the same reliability as current standard IV tubing.
Detailed Description: Study participants will have a SafeBreak Vascular installed in each of their existing or newly installed IV lines. The clinical literature shows in prospective observational studies that a mean of 9.2% of patients dislodge their peripheral IVs. SafeBreak Vascular is a medical device designed to aid in the prevention of unintended disruption and dislodgement of IVs, such as peripheral IVs, peripherally inserted central lines, central lines, etc. SafeBreak IV will be installed in each IV line between the study participant's catheter and the IV tubing that goes to the IV bag or IV pump. When a harmful force is placed on the IV line, SafeBreak Vascular is designed to separate so that the harmful force is removed from the line and IV dislodgement is prevented. SafeBreak Vascular has a valve in each end of the device. Upon separation, each valves closes, stopping the flow of fluid. The primary objective of the study is to determine if the delivery of IV medications and/or fluids with SafeBreak Vascular functions with the same reliability as current standard IV tubing. The number of IV dislodgements and IV restarts will be recorded. The study will also collect data for analysis concerning the following: * device design characteristics * certain human factors (patient or operator) associated with the use of the device * the impact of this device usage on clinician workflow * any unknown safety concerns * obtain preliminary data for use in designing a subsequent pivotal study of the device.
Study: NCT03505957
Study Brief:
Protocol Section: NCT03505957