Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 12:43 PM
Ignite Modification Date: 2025-12-24 @ 12:43 PM
NCT ID: NCT06177561
Brief Summary: The aim of this study is to prospectively explore the effectiveness and safety of LPE in clearing DSA, and to investigate the clinical efficacy of a combination therapy with LPE in patients undergoing genetic hematopoietic stem cell transplantation.
Detailed Description: We recruited 38 patients according to the inclusion criteria.(Inclusion criteria: 1. Serum DSA positive: MFI ≥ 2000;Between the ages of 18 and 65, male and female are not limited;Planned to undergo allo-HSCT , with an estimated survival time of\>3 months and an ECOG physical fitness score of 0-2;Normal renal function (BUN, Cr ≤ 1.5 times the upper limit of normal value, Ccr\>80ml/min). 2. Normal liver function (defined as ALT and AST ≤ 1.5 times the upper limit of normal. 3. TBiL ≤ 1.5 times the upper limit of normal). 4. ECG did not indicate any AMI, arrhythmia, or IAVB. 5. No CI (defined as LVEF ≥ 50%, normal MYO and BNP). 6. Non active RHD. 7. Chest X-ray or physical examination did not indicate cardiac dilatation. 8. Normal lung function (defined as FEV1, FVC, DLCO ≥ 60% predicted value).) Sample the peripheral blood of the patient at four timepoints(Before LPE treatment (D0); Before stem cell transfusion; On the 10th day of stem cell transfusion;On the 30th day of stem cell transfusion).Using multiplex bead analysis on the Luminex platform (Luminex Corporation, Austin, TX, USA), including the LAB screening PRA and LAB screening hybrid method, all patients' ethylenediamine tetraacetic acid (EDTA)-treated serum was tested for anti-HLA class I and class II antibodies.According to the manufacturer's instructions, the semi-quantitative measurement of DSA levels was performed by LAB screening single antigen beads assay (One Lambda; ThermoFisher), and the results were expressed as MFI.The cumulative DSA MFI was calculated by summing the MFI of all detected DSA under HLA antigen resolution. Evaluate the effectiveness of LPE by comparing it with the historical control group that has undergone TPE treatment in the past
Study: NCT06177561
Study Brief:
Protocol Section: NCT06177561