The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 5:36 PM
Ignite Modification Date: 2025-12-24 @ 5:36 PM
NCT ID: NCT05817968
Brief Summary: Measurements of esophageal pressure (Pes) as surrogate for pleural pressure are routinely performed in selected ICU patients to facilitate lung-protective ventilation and assess breathing effort. Pes is clinically measured via a nasogastric esophageal catheter. Current techniques involve balloon catheters but have some important disadvantages as they could deflate over time and require a very precise positioning and filling volume. A solid-state sensor does not have disadvantages associated with balloon catheters and may therefore be a useful alternative in clinical practice. This method-comparison study in adult mechanically ventilated ICU patients evaluates the accuracy of Pes measured using an esophageal catheter with a solid-state sensor as compared to a balloon catheter as reference standard.
Detailed Description: Measurements of esophageal pressure (Pes) as surrogate for pleural pressure are routinely performed in selected ICU patients to facilitate lung-protective ventilation and assess breathing effort. Pes is clinically measured via a nasogastric esophageal catheter. Current techniques involve balloon catheters but have some important disadvantages as they could deflate over time and require a very precise positioning and filling volume. A solid state sensor does not have disadvantages associated with balloon catheters and may therefore be a useful alternative in clinical practice. This method-comparison study in adult mechanically ventilated ICU patients evaluates the accuracy of Pes measured using an esophageal catheter with a solid-state sensor as compared to a balloon catheter as reference standard. Subjects will receive a standard balloon esophageal catheter and a solid-state pressure catheter for simultaneous measurements of Pes. Study population will be post-surgical ICU patients. Measurements will be performed during clinical mechanical ventilation settings which include a first phase of passive controlled ventilation (patient is still sedated after surgery) as well a phase of partially-assisted ventilation where the patient's breathing effort has resumed and is assisted by the ventilator. During both phases, 10-15 minutes of tidal breathing will be recorded.
Study: NCT05817968
Study Brief:
Protocol Section: NCT05817968