The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 5:10 PM
Ignite Modification Date: 2025-12-24 @ 5:10 PM
NCT ID: NCT01827150
Brief Summary: The present proposal investigates the influence of energy drinks on the blood oxygenation concentration of the optic nerve on healthy subjects. On a voluntary basis, 15 subjects, man or woman, will be selected to undergo this experiment. Many factors can influence the blood oxygenation concentration of the optic nerve, which will be measured also during this experiment, namely: Intra ocular pressure (IOP), blood pressure, heart rate and systemic hemoglobin saturation. The subjects will have to be tested twice to test the two conditions of this experiment: 1. The effect after the intake of a can of Redbull (250 ml) 2. The difference with the intake of 250 ml of water The purpose of this study is to determine if the blood oxygenation concentration of the optic nerve varies after having ingested 250 ml of Redbull. Our hypothesis are: 1. The blood oxygenation concentration of the optic nerve measured with OSOME (see detailed description below), decreases due to the consumption of the energy drink Redbull compared to an equal volume of water. 2. The IOP measured with iCare tonometer decreases after the consumption of the energy drink Redbull compared to an equal volume of water. 3. The systemic blood pressure, measured with an automatic sphygmomanometer remains constant after ingestion of Redbull energy drink or an equal volume of water. 4. Heart rate, measured with a sphygmomanometer automatic increases after taking a Redbull energy drink compared to an equal volume of water. 5. The rate of systemic hemoglobin saturation measured with a pulse oximeter remains constant after the ingestion of a Redbull energy drink or an equal volume of water.
Detailed Description: The blood oxygenation will be assessed using a machine called the OSOME. The online spectroreflectometry oxygenation measurement in the eye (OSOME) was used to measure eye fundus oxygenation, more precisely optic nerve head capillaries structures oxygenation, by full spectrum reflectometry (1020 wavelength from 400 to 700nm) in real time (O.S.O.M.E., Faubert \& Diaconu US patent # 5,919,132) with 2% accuracy. It includes a fundus camera (Topcon, Osaka, Japan) coupled with a digital video camera (USB) and a detection unit composed of a multi-channel spectrograph and a charged coupled device (CCD). In order to use this machine, upon arrival, the patient's right eye needs to be dilated with drops of proparacaine hydrochloride 0.5%, tropicamide 1% and phenylephrine hydrochloride 2.5%. The patient is required to rest for 20 minutes to allow a complete dilatation of the pupil before using the OSOME.
Study: NCT01827150
Study Brief:
Protocol Section: NCT01827150