Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 4:50 PM
Ignite Modification Date: 2025-12-24 @ 4:50 PM
NCT ID: NCT04327050
Brief Summary: This study uses magnetic anchored guidance system to treat early gastric cancer by endoscopic mucosal dissection to test the advantages of magnetically anchored guidance system for surgical field exposure during endoscopic mucosal dissection.
Detailed Description: Gastric cancer is the second most common malignant tumor in China, with the highest mortality rate among all types of malignant tumors. Surgical resection is still the most effective treatment for gastric cancer. Minimally invasive surgery breaks the traditional surgical concept that the laparotomy must be performed by laparotomy. It can complete the operation that required a large incision with minimal incision trauma, and has the advantages of less trauma, faster recovery and fewer complications. At present, the application of gastroscopy and laparoscopy for early gastric cancer has reached consensus at home and abroad. Endoscopic mucosal resection of early gastric cancer is suitable for patients with intramucosal cancer and no lymph node metastasis. However, the unclear exposure of the surgical field during the operation causes difficulty in operation or conversion to open surgery is a difficult problem facing this technique. The project designed a magnetic pulling unit that can be connected through an endoscope, including external abdominal magnets, internal abdominal magnets, connecting hooks, and micro surgical tweezers. Using magnetic anchoring technology, the magnetic pulling unit is anchored to the abdominal wall, and micro surgical tweezers are used. The tumor tissue is pulled indirectly, so that the mucosa is lifted up, which is beneficial to the peeling of the submucosa. This method increases the operating space of the main hand of the endoscope, and at the same time, the magnetic clamp is used to connect the clamps so that they can move in all directions, so as to achieve the desired traction of the tumor tissue site, fully expose the surgical field, and facilitate surgical anatomy.
Study: NCT04327050
Study Brief:
Protocol Section: NCT04327050