Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 4:12 PM
Ignite Modification Date: 2025-12-24 @ 4:12 PM
NCT ID: NCT02772666
Brief Summary: This study is to evaluate the ability of a newly designed device, Optic Nerve Glass (O-Glass) to detect relative afferent pupillary defect (RAPD). In this prospective study, 44 patients (diagnosed RAPD- positive) enrolled the study. They were examined for an RAPD by O-Glass and also manual swinging flashlight method (SFM) . This newly designed instrument captures and records eye pictures. The images will be processed and analyzed using computerized software to calculate pupillary measurements.
Detailed Description: Pupil response to light stimulation is a basic clinical approach to the assessment of a patient with visual loss. Asymmetric response may indicate a relative afferent pupillary defect (RAPD). The rapid detection device for relative afferent pupillary defect (present device) is a newly designed portable facility with computerized software on a mobile device. This allows for field ophthalmic examination and identification of RAPDs quickly and accurately and also record pupillary movements for further processing and analysis or send the information and images via Wi-Fi. We aimed at comparing and evaluating this device with available methods to develop a test which is practically easy and quick with objective results and no need for specialist interpretation, so that any technician can perform the test automatically. Distinctive software allows simple use of the device by field personnel with minimal training. Each patient was investigated by swinging flashlight method and the newly constructed automated O-glass. The swinging flashlight test procedure, also called as Marcus Gunn Test, is well known in ophthalmology science.The hardware for this device includes 4 different parts: Camera and optics, light control system, power control system, and the microcontroller.The two main components of the software are the ability to communicate with the hardware wirelessly, and the pattern recognition system.
Study: NCT02772666
Study Brief:
Protocol Section: NCT02772666