Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2026-03-26 @ 3:17 PM
Ignite Modification Date: 2026-03-26 @ 3:17 PM
NCT ID: NCT07391969
Brief Summary: Evaluation of new supraglottic device SaCo VLMA for laparoscopic procedures under general anesthesia in comparison with other airway management methods including other supraglottic devices. The parameters noted will be: demographic data, time for placement of SGA counted from moment of grabbing device by operator to correct placement, subjective evaluation of ease of insertion of SGA in 5 step Borg scale, peak pressure, lung compliance, achieved tidal volume before creating pneumoperitoneum, after creating pneumoperitoneum, visualization of glottis on monitor of camera or fiberoptic scope.
Detailed Description: Evaluation of new supraglottic device SaCo VLMA for laparoscopic procedures under general anesthesia in comparison of other supraglottic devices and other methods of airway management for such procedures. The airway management for laparoscopic surgery can be achieved by either endotracheal intubation (ET) or use of supraglottic devices (SGA). However, many anesthesiologist still prefer ET over use of SGA because of possible problems with adequate ventilation during pneumoperitoneum. New SGA devices as video laryngeal mask offer important advantage which is continuous control of proper placement of SGA during anesthesia. In case of ventilation difficulties like leak, high peak pressure, low tidal volume SGA VLM allow to check if the problem is related to malposition or changed of position of SGA and allow for correction under control of vision. The aim of this study is to evaluate the characteristics of the SaCo VLMA video laryngeal mask in the hands of experienced anesthesiologists. All patients will be anesthetized following the same protocol: Intravenous induction with propofol, FNT, midazolam, rocuronium in standard doses. After achieving proper muscle relaxation SaCo VLMA was inserted following manufacturer recommendations. For maintaining anesthesia sevoflurane was used. After induction for anesthesia the airway of the patient will be secured by one randomly chosen device: SaCo VLMA or other SGA or ET. The parameters noted will be: demographic data, time for placement of SGA counted from moment of grabbing device by operator to correct placement, subjective evaluation of ease of insertion of SGA in 5 step Borg scale, peak pressure, lung compliance, achieved tidal volume before creating pneumoperitoneum, after creating pneumoperitoneum, visualization of glottis on monitor of camera or fiberoptic scope.
Study: NCT07391969
Study Brief:
Protocol Section: NCT07391969