Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 4:41 AM
Ignite Modification Date: 2025-12-25 @ 4:41 AM
NCT ID: NCT01333618
Brief Summary: It has been demonstrated that implantation of inferior vena cava filter was safe and effective in the prevention or reduction of fatal pulmonary thromboembolism in numerous clinical researches. When acute deep venous thrombosis need transcatheter thrombolysis, transfemoral Günther Tulip Filter implantation could avoid catheter across the Günther Tulip Filter. Although incidence of significant filter tilting (\>10°) is not high (13%-16%), severe tilting of the Günther Tulip Filter may be associated with difficulty or sometimes impossibility of retrieval. It has been reported that a simple technique of keeping tension of the delivery system may prevent significant tilting of the transjugular Günther Tulip Filter in an in-vitro study. But no clinical study of prevention transfemoral Günther Tulip Filter from tilting has been reported. The investigators conducted a randomized, controlled study to test whether the introducer curving technique is useful to decrease the extent of tilting of transfemoral Günther Tulip Filter.
Detailed Description: The study was designed as a double-blind randomized controlled trial, with research assessors and patients intended to be blind to the intervention status. The staff members performing the assessment were not involved in implementing any aspect of the intervention. 108 patients were randomized to accept curving introducer Günther Tulip Filter and transcatheter thrombolysis or straight introducer Günther Tulip Filter and transcatheter thrombolysis. The assessments include the tilting angle between the axes of inferior vena cava and Günther Tulip Filter after implantation; the tilting angle between the axes of inferior vena cava and Günther Tulip Filter before retrieval; the fluoroscopy time of Günther Tulip Filter retrieval; the rate of retrieval hook adhering vascular wall; the success rate of retrieval.
Study: NCT01333618
Study Brief:
Protocol Section: NCT01333618