Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 4:33 AM
Ignite Modification Date: 2025-12-25 @ 4:33 AM
NCT ID: NCT03567018
Brief Summary: In this study the investigators plan to enroll a total of 25 evaluable volunteers (volunteer population) for the development and optimization of perforator imaging protocols and 50 evaluable clinical patients receiving flap procedures at OSUMC for the clinical validation of the optimized protocol. No extrinsic MR contrast agent will be injected. Clinical patients' MRI images will be evaluated independently by radiologists and plastic surgeons and compared to the clinical CTA images.
Detailed Description: The overall objective of this pilot study is to develop and optimize preoperative MRA imaging protocols for various perforators commonly used in flap surgery with phantoms and healthy volunteers and to obtain clinical validation of the optimized protocols with a group of patients receiving flap surgery at The OSU Wexmer Medical Center. Data obtained in this study may also serve as the basis for statistical planning of future clinical trials. Based on previous experience with other magnetic resonance imaging (MRI) techniques, the investigators hypothesize that optimal MRA images can only be obtained with a carefully selected combination of imaging hardware, acquisition, and postprocessing factors. The main objective of this pilot study is to determine this optimal combination through the comparison of image between different combinations. The secondary objective of this pilot study is to evaluate, both qualitatively and quantitatively, the quality of the optimized MRA images and compare them with clinical CTA images. The primary hypothesis is that the quality of the optimized MRA images is at least comparable to that of the CTA images. The quantitative measurements obtained from this pilot population will also serve as the preliminary data for future studies and be used in statistical calculations that determine their study population.
Study: NCT03567018
Study Brief:
Protocol Section: NCT03567018