The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 2:49 PM
Ignite Modification Date: 2025-12-24 @ 2:49 PM
NCT ID: NCT01394159
Brief Summary: The aim of this research study is to identify the best needle for performing biopsy during EUS procedures. There are two types of needles for performing biopsy: A FNA needle that provides a small sample of tissue for analysis and a 22G ProCore needle that provides larger amount of tissue. It is not clear at this point which of the two needles is superior for performing biopsy. This study will attempt to identify the better needle by assessing the performance of both needles in a randomized fashion.
Detailed Description: In this randomized trial, the 22G standard fine needle aspiration needle was compared with the newly developed 22G ProCore needle for sampling pancreatic mass lesions during endoscopic ultrasound. Patients were randomized into the two needle groups and then various outcomes were compared between the two needle types, including the number of passes needed to establish a diagnosis, the ability to procure enough tissue sample to be able to make a diagnosis, the rates of needle failure and complication rates.