Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 4:18 AM
Ignite Modification Date: 2025-12-25 @ 4:18 AM
NCT ID: NCT04991220
Brief Summary: The aim of this study is to investigate whether the change in pleth variation index (PVI) according to preoxygenation can predict hypotension during anesthesia induction.
Detailed Description: In patients with hypovolemia or dehydration, pulse pressure variation can be increased by spontaneous forced inspiratory breathing. PVI is a noninvasive method of indicator of fluid responsiveness like purse pressure variation. We expected that the amount of change in PVI between at the time of entering operating room and after preoxygenation with forced inspiration method could be different depending on the patient's volume status. After entering operating room, monitoring devices, anesthesia depth sensor, and Radical-7® Pulse CO-Oximeter® are attached. Patients rest for 5 minutes, and then baseline systolic blood pressure, diastolic blood pressure, mean blood pressure, and heart rate are collected every 1-minute. Pleth variability index (PVI), perfusion index (PI) are also measured continuously. For pre-oxygenation of anesthesia, take 8 deep breaths at flow 10 l/min of 100% oxygen for 1 minute with maximally forced inspiration. After that, for 2 minutes, patients breathe as usual while maintaining oxygen supply. until tracheal intubation or laryngeal mask insertion. Anesthesia is induced with target concentration infusion of 4.0 ng/ml of remifentanil and 4.0 ug/ml of propofol. When the patient loses consciousness, rocuronium 1.0 mg/kg is administrated and endotracheal tube or laryngeal mask is inserted 2 minutes after. PVI, PI, blood pressure, and heart rate are measured until tracheal intubation or laryngeal mask insertion. Anesthesia induction-related hypotension is defined as a decrease in mean arterial pressure below 60 mmHg at any timepoint from baseline parameter collection to until airway device insertion. The parameters are analyzed by comparing between groups with and without anesthesia induction-related hypotension.
Study: NCT04991220
Study Brief:
Protocol Section: NCT04991220