Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 4:15 AM
Ignite Modification Date: 2025-12-25 @ 4:15 AM
NCT ID: NCT02501720
Brief Summary: Post burn flexion contractures are common in pediatric age group. Release of contracture and coverage with full thickness skin graft (FTSG) is a widely used procedure for this problem. This procedure is routinely done under tourniquet control because bloodless operative field is essential to visualize important neurovascular structures in hand. Use of tumescent technique without a tourniquet is gaining acceptance because it avoids complications associated with tourniquet use, maintains a blood less surgical field and decreases operative time. Furthermore use of tumescent anesthesia often results in better surgical outcomes. Although the benefits of tumescent technique used in wide awake hand surgery are well documented, epinephrine at a concentration of 1:1 000,00 has also been used as a replacement for pneumatic tourniquet for release of hand contracture in infants and adults under general anesthesia. Thus epinephrine 1:1,000,00 in saline solution can be a potential replacement for a tourniquet in hand surgeries done under general anesthesia.
Detailed Description: Post burn flexion contractures are common in pediatric age group. Release of contracture and coverage with full thickness skin graft (FTSG) is a widely used procedure for this problem. This procedure is routinely done under tourniquet control because bloodless operative field is essential to visualize important neurovascular structures in hand. Use of tumescent technique without a tourniquet is gaining acceptance because it avoids complications associated with tourniquet use, maintains a blood less surgical field and decreases operative time. Furthermore use of tumescent anesthesia often results in better surgical outcomes. Although the benefits of tumescent technique used in wide awake hand surgery are well documented, epinephrine at a concentration of 1:1 000,000 has also been used as a replacement for pneumatic tourniquet for release of hand contracture in infants and adults under general anesthesia. Thus epinephrine 1:1,000,000 in saline solution can be a potential replacement for a tourniquet in hand surgeries done under general anesthesia. To the investigators' knowledge no study has so far been done to compare the outcome of release of post burn flexion contractures under tumescent technique with general anesthesia or under tourniquet control with general anesthesia.
Study: NCT02501720
Study Brief:
Protocol Section: NCT02501720