Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 3:44 AM
Ignite Modification Date: 2025-12-25 @ 3:44 AM
NCT ID: NCT03449602
Brief Summary: Consecutive patients who are planned to undergo a medical thoracoscopy for obtaining pleural biopsies will be enrolled in the study. One hundred subjects will be randomized in 1:1 ratio to undergo thoracoscopy to the following groups: Group A (mini-thoracoscopy) Group B (Conventional rigid thoracoscopy) Primary outcome: (a) diagnostic sensitivity of mini-thoracoscopy and conventional rigid thoracoscopy in the diagnosis of exudative pleural effusions
Detailed Description: A significant proportion of patients with pleural effusions remain undiagnosed after performance of diagnostic procedures including cytological and microbiologic analysis of the pleural fluid and closed pleural biopsies. In this study, the investigators plan to compare the yield and safety of mini-thoracoscopy and conventional rigid thoracoscopy with the larger diameter scope. This is a prospective study that will be conducted at the Thoracic Endoscopy Suite of the Department of Pulmonary Medicine, PGIMER, Chandigarh. Consecutive patients who are planned to undergo a medical thoracoscopy for obtaining pleural biopsies will be enrolled in the study One hundred subjects will be randomized in 1:1 ratio to undergo thoracoscopy. The randomization sequence will be generated using a computer (in blocks of 10), and the allocation will be placed in opaque sealed envelopes. The patients will be randomized to the following groups: Group A (mini-thoracoscopy): The mini-thoracoscope manufactured by Richard Wolf GmbH, Knettligen, Germany will be used. It has an outer diameter of 5.5 mm and a working channel diameter of 3.5 mm. Group B (Conventional rigid thoracoscopy): The rigid thoracoscope manufactured by Richard Wolf GmbH, Knettligen, Germany will be used that has an outer diameter of 10 mm and channel internal diameter of 5 mm. Primary outcome: (a) diagnostic sensitivity of mini-thoracoscopy and conventional rigid thoracoscopy in the diagnosis of exudative pleural effusions.
Study: NCT03449602
Study Brief:
Protocol Section: NCT03449602