Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 3:37 AM
Ignite Modification Date: 2025-12-25 @ 3:37 AM
NCT ID: NCT00817102
Brief Summary: This study will evaluate the effectiveness of CorCTA by comparing the results of the test with another imaging method called Fractional Flow Reserve (FFR), which is done as a part of the cardiac catheterization.
Detailed Description: Invasive X-ray coronary angiography remains the "reference standard" for the evaluation of coronary artery stenoses. Recently, coronary artery computed tomography angiography (CorCTA) has been introduced as a non-invasive method for the evaluation of coronary artery stenoses and has been shown to be highly accurate in stenosis detection when compared to invasive X-ray angiography. While invasive X-ray angiography and CorCTA evaluate morphological features of coronary arterial plaques, fractional flow reserve is an invasive measure of the hemodynamic significance of a stenosis obtained in the catheterization laboratory by measuring changes in intracoronary arterial pressure before and after maximal vasodilation induced by intracoronary adenosine. An FFR value less than 0.75 has been shown to predict ischemia in vascular beds distal to the stenosis by radionuclide perfusion modalities and has been shown to be associated with worse outcomes. Therefore, FFR is considered to be an invasive hemodynamic "reference standard" for the evaluation of the hemodynamic significance of coronary arterial stenoses. While intravascular ultrasound (IVUS) can provide additional morphological information in intermediate stenoses, it can not provide further functional information and cannot be used in more significant stenoses as the IVUS probe cannot be advanced through stenotic lesions. We are currently conducting investigation in the validation of CorCTA against FFR in intermediate coronary artery stenoses (40-70%) (see below under "Preliminary Data"). However, CorCTA has not been validated against invasive hemodynamic measurements of fractional flow reserve in patients with stenoses \>70% by invasive X-ray angiography. We hypothesize that CorCTA-derived measurements are accurate in the diagnosis of hemodynamically significant coronary artery stenoses, using FFR as the reference standard in patients with coronary artery stenoses\>70%.
Study: NCT00817102
Study Brief:
Protocol Section: NCT00817102