Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 3:31 AM
Ignite Modification Date: 2025-12-25 @ 3:31 AM
NCT ID: NCT02480205
Brief Summary: There is currently a consensus that non-invasive ventilation (NIV) in preterm infants is preferred over intubation. There are two ways of delivering NIV in preterm infants, nasal continuous positive airway pressure (CPAP) or nasal intermittent positive pressure ventilation (NIPPV), where ventilator inflations are delivered intermittently over a fixed end-expiratory pressure. The synchronization in conventional mode is very difficult to obtain in premature infants. In all ventilation modes PEEP (end-expiratory pressure) is fixed. Considering that preterm infants are more likely to develop atelectasis, an active and ongoing management of the PEEP is very important to prevent de-recruitment. A new respiratory support system (NeuroPAP) was developed to address these issues (synchronization problems and control the PEEP). It uses the electrical activity of the diaphragm (EDI) to control the ventilator assist continuously, both during inspiration (principle of NAVA mode) and also during expiration (based on tonic Edi level).
Detailed Description: The mode NeuroPAP will work with the continuous Edi-level and deliver pressures according to the Edi-signal x set NeuroPAP-level, over the whole breath (inspiration and expiration). The NeuroPAP will work between two pressure levels set by the user and named higher Pressure limit (Plimit) and minimum Pressure (Pmin). A safety upper pressure limit (UPL) will also be set. A backup ventilation will be possible. A specific gastric tube equipped with an array of microelectrodes (Edi catheter, Maquet, Solna, Sweden) will be installed after inclusion, by the same oral or nasal route as the tube previously in place. Patients will then be ventilated in the 5 aforementioned conditions: * On conventional NIPPV device on clinical settings for a 30 minute period. The investigators will note the mean airway pressure being delivered with the clinical settings and the resulting peak Edi, as well as neural respiratory rate, tonic Edi, Fraction of inspired oxygen (FiO2), and Oxygen saturation by pulse oximetry (SpO2). * With NeuroPAP without modification of Pmin (=peep). The exchange of the nasal interface may be necessary, depending on the original interface. FiO2 will initially be the same as previously set in conventional NIPPV. The Pmin will initially be set at the level of PEEP used during conventional NIPPV. A titration maneuver will be conducted to identify the optimal NeuroPAP level. The infant will be ventilated for one hour. Clinical adjustments in pressures and FiO2 are permitted. Safety termination will be established. * NeuroPAP with adjusted Pmin: the Pmin in NeuroPAP will be reduced by 2 cm H2O, with the same NeuroPAP level. The patients will be ventilated for one hour. * CPAP delivery with NeuroPAP device: the device will be switched to CPAP mode, for a 15 minute period * A second 30 minutes period of the conventional NIPPV will be conducted.
Study: NCT02480205
Study Brief:
Protocol Section: NCT02480205