Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 3:24 AM
Ignite Modification Date: 2025-12-25 @ 3:24 AM
NCT ID: NCT03074305
Brief Summary: The aim of the study is to compare angiographic outcomes following revascularization using drug-eluting balloon (DEB) versus 2nd generation drug-eluting stent (DES) in treatment of Bioresorbable Vascular Scaffold Restenosis.
Detailed Description: The bioresorbable vascular scaffold (BRS) has been emerged as new therapeutic option in percutaneous coronary intervention for coronary artery disease. Although 2nd generation drug-eluting stent (DES) has enhanced the efficacy and safety of DES, However, along with the widespread use of this newer generation DES in most clinical conditions, including high-risk patients with more complicated lesion profiles, ISR has continued to be a major concern, even in the era of newer generation DES. In this regards, the concept of BRS has introduced and has showed promising results. Nevertheless, previous reports showed that even BRS has not been free from restenosis, leading target lesion revascularization up to 7.4% during 3-year follow up. Currently, previous researches which comparedsafety and efficacy of treatment options for ISR lesion showed similar clinical outcomes following 2 representative options, namely, drug-eluting balloon or drug-eluting stent. In this regards, current European Society of Cardiology/European Association for Cardiothoracic Surgery (ESC/EACTS) guidelines recommend drug-eluting balloon (DEB) and 2nd generation DES as class IA recommendations for the treatment of BMS or DES-ISR. However, all the previous reports evaluated the ISR of metallic stents, and there has been no evidence for treatment option for BRS ISR. Therefore, the Smart Angioplasty Research Team: Safety and Efficacy of Drug-Eluting Balloon versus 2nd Generation Drug-Eluting Stent in Treatment of In-Bioresorbable Vascular Scaffold Restenosis (SMART-BRS-ISR) trial will randomly allocate patients with BRS ISR into DEB or 2nd generation DES and compare safety and efficacy of both treatment options.
Study: NCT03074305
Study Brief:
Protocol Section: NCT03074305