Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 3:18 AM
Ignite Modification Date: 2025-12-25 @ 3:18 AM
NCT ID: NCT04679805
Brief Summary: The use of intra coronary physiological assessment with fractional flow reserve (FFR) is nowadays the standard approach to define ischemia-inducing stenosis and guide myocardial revascularization strategy in patients with coronary artery disease. Further, FFR has been shown to be a strong and independent predictor of major adverse cardiac events after stent implantation. A lower value of FFR after stent implantation is associated with a worse clinical prognosis, without a clearly defined threshold above which clinical follow up are similar for all FFR values. Among 750 patients in the Fractional Flow Reserve Post-Stent Registry, the event rate was 29.5% in patients with FFR\<0.80 compared to 9 4.9% in patients with FFR\>0.95 (p\<0.001). However, FFR remains poorly adopted in many cathlabs, partly because of procedural time, discomfort or sides effect during hyperemia, non-uniform adenosine response and economical constraints. This leads to the validation of resting indices (instantaneous wave-free ratio (iFR), diastolic pressure ratio (dPR), and resting full-cycle ratio (RFR) among others). Those indices evaluate coronary physiology without the use of maximal hyperemia and have 15 slightly different threshold compared to FFR (≤0.89 vs 0.80, for iFR and RFR, and FFR 16 respectively).In the VALIDATE RFR study, a head-to-head comparison of RFR and iFR from a retrospective analysis, diagnostic accuracy of RFR was 97.4% with an area under the curve 1 (AUC) of 99.6%. In the more recent RE-VALIDATE RFR study, 431 patients with 501 lesions 2 were prospectively evaluated for the diagnostic performance of RFR in all-comers patients. Compared to iFR, RFR achieved high diagnostic accuracy, sensitivity and specificity. These are the reasons why we designed a prospective, non-randomized, clinical trial, to better 18 explore the value of RFR before and after PCI in real live and after optimization by post dilation 19 in all-comers patients with coronary artery disease in the Middle East region..
Study: NCT04679805
Study Brief:
Protocol Section: NCT04679805