The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 2:28 PM
Ignite Modification Date: 2025-12-24 @ 2:28 PM
NCT ID: NCT04299659
Brief Summary: The aim of this study is to investigate and compare the validity of four different input methods for Landolt Cs, i.e. the proportion of correct gap positions in relation to the total number of performances. The four input methods are a numeric keypad, an eight-positions rocker switch, a remote control and voice feedback.
Detailed Description: The measurement of visual acuity is the most frequent and one of the most important ophthalmological functional investigations. Therefore, it is particularly important to find a measuring procedure with as little input errors as possible. The 8-position Landolt C (LC) is the internationally accepted, well-standardised optotype for the determination of visual acuity. Usually, the subjects informs the examiner verbally about the perceived position of each LC. According to the current literature, about 20 to 30 % of the population suffers from a right/left weakness. Furthermore, language barriers are an additional considerable hurdle. Therefore, it is important to find an input method for the LC gap positions with minimal entry mistakes. In oder to avoid the thresholding procedure and its inherent difficulties, highly supra-threshold (10 times above the previously determined individual central visual acuity threshold) 8-position LCs are presented. The study compares four input methods for entering of the Landolt C gap positions: a modified numeric keypad, an 8-position rocker switch, a modified TV remote control and voice/verbal feedback. Each subject will perform all four input methods, with 2 test runs of 16 Landolt C presentations, each. A forced-choice method will be applied, i.e. the test is not continued until the test person has responded ot each single presentation. Regardless of whether the entry was correct or incorrect, the next Landolt C is displayed. The optotypes are presented using modified version of the Freiburg Visual Acuity and Contrast Test (FrACT), which allows to present the 8-position Landolt Cs in a standardized way on a video display unit (VDU). The sequence of the input methods is randomized. This study is carried out in a "within-subject design", i.e. all test persons go through all test conditions and serve as their own controls.
Study: NCT04299659
Study Brief:
Protocol Section: NCT04299659