Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 2:34 AM
Ignite Modification Date: 2025-12-25 @ 2:34 AM
NCT ID: NCT00955734
Brief Summary: Many surgeons pursue volar plating of the distal radius to allow earlier post-operative wrist motion. Early motion is generally prescribed in the belief that it will result in greater final motion without compromising fixation. However, studies have failed to demonstrate clinically significant improvement in final wrist motion (\> 1 year follow up) compared to treatments requiring longer immobilization such as external fixation or bridge plating.
Detailed Description: Many surgeons pursue volar plating of the distal radius to allow earlier post-operative wrist motion. Early motion is generally prescribed in the belief that it will result in greater final motion without compromising fixation. However, studies have failed to demonstrate clinically significant improvement in final wrist motion (\>1 year follow up) compared to treatments requiring longer immobilization such as external fixation or bridge plating (McQueen 1996, Handoll 2003, Atroshi 2006, Krishnan 2003, Sommerkamp 1994, Grewal 2005). Only one study to date has attempted to define the early effects of wrist mobilization following volar plate fixation of the distal radius (Lozano-Calderon 2008). That study prospectively enrolled 60 patients and randomized them to begin wrist motion at 2 weeks (range 7 days - 13 days) or 6 weeks (range 42 to 49 days) postoperatively. This study found no significant difference in subjective or objective outcome measures at 3 or 6 months follow up. However, the investigation had several weaknesses. First, there was no attempt to confirm adherence to the immobilization protocols. Those in the late motion group were not casted but remained in orthoplast splints which could be easily removed. Secondly, this investigation collected data only at 3 and 6 months which prohibited them from commenting on the rate of improvement during the early weeks after mobilization. The authors acknowledged these limitations and further noted that no evaluation of patient cost was performed. Finally, radiographic evaluations in this study did not include analysis of change in alignment from immediate postoperative films. Thus, the literature to date suggests that early mobilization of the volarly plated distal radius is safe but does not improve final wrist motion. The benefits of mobilization in the early postoperative period though have not been clearly defined. This project proposes to fill this void in the literature and determine if early mobilization is an effective measure to hasten recovery of motion and function.
Study: NCT00955734
Study Brief:
Protocol Section: NCT00955734