Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 2:27 AM
Ignite Modification Date: 2025-12-25 @ 2:27 AM
NCT ID: NCT06144034
Brief Summary: In epileptic and non Epileptic children, the full dentition of each patient was split into four quadrants, starting from the upper right quadrant (1) and moving clockwise until the lower right quadrant (4). Bundled into two groups: quadrant (1+3) vs. (2+4). After randomization, each of these pairs of quadrants had the same treatment modality; test quadrants received treatment with airflow to remove soft biofilm, and ultrasonic scaler for areas with calculus deposits, and control quadrants were treated with conventional rubber cup polishing to remove soft biofilm and ultrasonic scaler for calculus deposits.
Detailed Description: The treatment of each quadrant was administered sequentially, beginning with the upper right quadrant. Treatment duration was measured in seconds from the start of treatment in each quadrant until the removal of all disclosed biofilm and calculus. This process was repeated for each quadrant individually. And intra-oral photographs were taken before, immediately after treatment, and at follow-up time. Conventional treatment was conducted after biofilm disclosure by a rubber cup and prophylaxis paste spearmint (Kemdent Works, Purton. Swindon, Wiltshire. SN5 4HT, UK). The power setting was between 70% and 100%. The rubber cup was used until all biofilm was removed, then, if present, calculus was removed by Electro Medical Systems (EMS) ultrasonic scaler with a power setting between 3-6 on the Airflow control panel. For Airflow, treatment was conducted after biofilm disclosure. The powder chamber of the air polishing device was filled with low-abrasive erythritol powder, according to the manufacturer's instructions. The tip of the handpiece was positioned at an angle of 70° to the surface of the tooth to be polished at 3 mm from the tooth surface. Once activated, a non-stop movement from mesial to distal and distal to mesial in a smiley face shape starting from the gingival sulcus and moving upwards coronally to the incisal to cover the entire clinical crown was performed, with a power setting ranging from 3-6 on the control panel of the airflow device. EMS ultrasonic scaler was used to remove calculus if present with a power ranging from 3-6.
Study: NCT06144034
Study Brief:
Protocol Section: NCT06144034