Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 2:16 AM
Ignite Modification Date: 2025-12-25 @ 2:16 AM
NCT ID: NCT00711360
Brief Summary: The new BIOTRONIK implantable cardioverter defibrillator (ICD) family Lumax 540 is capable of measuring the intrathoracic impedance on a daily basis and transmission of impedance trend data via the Home Monitoring technology. In future, this will allow for automatic early detection of imminent decompensation at a presymptomatic stage and immediate initialization of clinical meaningful therapeutic interventions preventing heart failure related hospitalizations. The aim of this investigation is to record long-term impedance trends in heart failure patients with and without heart failure related events (hospitalizations due to acute decompensation) in order to develop algorithms for device-based early detection and warning of HF deterioration accompanied by pulmonary congestion.
Detailed Description: The new BIOTRONIK implantable cardioverter defibrillator (ICD) family Lumax 540 is capable of measuring the intrathoracic impedance on a daily basis and transmission of impedance trend data via the Home Monitoring technology. In future, this will allow for automatic early detection of imminent decompensation at a presymptomatic stage and immediate initialization of clinical meaningful therapeutic interventions preventing heart failure related hospitalizations. The aim of this investigation is to record long-term impedance trends in heart failure patients with and without heart failure related events (hospitalizations due to acute decompensation) in order to develop algorithms for device-based early detection and warning of HF deterioration accompanied by pulmonary congestion. Lumax is the name of a family of implantable ICDs. The primary objective of the therapy is the prevention of sudden cardiac death. The aim is to automatically detect and terminate cardiac arrest caused by ventricular tachyarrhythmia. All major therapeutical approaches from the field of cardiology and electrophysiology are contained within the Lumax family. Furthermore, the device is capable of treating bradycardia arrhythmias and congestive heart failure. Congestive heart failure is treated with cardiac resynchronization therapy with multisite ventricular pacing known as cardiac resynchronization therapy (CRT). The integrated Home Monitoring component can provide information about occurring rhythm disturbances and delivered therapies close to real time as well as by intracardiac electrogram (IEGM) Online HD®. Furthermore, statistical data about the patient's condition as well as information about the integrity status of the implant itself are sent. The implantation of an ICD is a symptomatic therapy with the following objectives: * Termination of spontaneous ventricular fibrillation (VF) through shock delivery * Termination of spontaneous ventricular tachycardia (VT) by means of antitachycardia pacing (ATP); in case of ineffective ATP or hemodynamically not tolerated VT with shock delivery * Cardiac resynchronization by multisite ventricular pacing (triple-chamber implant) * Compensation of bradycardia through ventricular (single-chamber implant) or atrioventricular sequential pacing (dual- and triple-chamber implant)
Study: NCT00711360
Study Brief:
Protocol Section: NCT00711360